Precor RBK 800 warranty Completing the Console Installation P30 and P20

Page 35

Installing the Console

33

Completing the Console Installation (P30 and P20)

Before you complete the final installation steps, double-check the connections you have made. Make sure that all cables are fully and securely connected, and that any unneeded cables are tied back properly.

To complete the installation:

1.Feed extra cable back into the neck tube.

2.Tilt the control console backward (toward yourself) until the tab on the top edge of its back plate slides along the top edge of the console mount and the screw holes align properly.

3.Insert the four ⁵₈-inch flat head screws through the holes in the console mount and thread them into the holes in the back plate on the console. Partially tighten the screws using a ⁵₈-inch hex wrench.

4.Line up the two small tabs at the bottom of the console’s back cover with the slots at the bottom of the console case. Insert the tabs into the slots.

5.Insert the two #8–32 x ¹₂-inch Phillips-head screws that you removed earlier into the holes at the top edge of the console’s back cover. Tighten the screws fully.

Important: Use caution not to pinch the cables between the back cover and PVS mounting screw heads.

6.Fully tighten the four mounting screws (partially tightened in step 3) using a ⁵₃₂-inch hex wrench.

Verifying That the Heart Rate Display Is Operational

To verify that the heart rate display is operational:

1.Begin exercising on the equipment.

2.Grasp both touch-sensitive handlebars.

Note: The heart rate is read within ten seconds. During that time, the heart on the display flashes.

3.Look at the HEART RATE display. After a few seconds, a number appears indicating your heart rate.

4.If a number does not appear in the HEART RATE display, check the cable connection to make sure it is properly connected.

Image 35
Contents Page Page Page Intellectual Property Notice Edition InformationTrademark Note Safety Precautions Important Safety InstructionsPage Educating Users Regulatory Notices for the Rfid Module Hazardous Materials and Proper DisposalProduct Recycling and Disposal Void the user’s authority to operate the equipment Radio Frequency Interference RFIFederal Communications Commission, Part Industry CanadaCardiovascular Type Equipment Safety Approvals for Cardiovascular EquipmentRegulatory Notices for Cardiovascular Exercise Equipment European ApplicationsUser’s authority to operate the equipment IEC-320 C13 and C14 plugs Obtaining Service Obtaining Updated DocumentationTable of Contents Commercial Cardiovascular Equipment Limited Warranty Assembling the Exercise Bike To prepare the exercise bike for assemblyTo unpack the bike Unpacking the EquipmentFasteners Hardware Kit not to scaleRequired Tools To attach the seat back Attaching the Seat Back and Bottle HolderTo attach the bottle holder Installing the Upright Support and CablesTo prepare the bike for installation of the upright support Is properly installedRear cover removal Upright support insertion Bolting the upright support into place To level the unit Making Sure the Unit Is StableBreaking in the Equipment Page Threading the Cable Assembly P80 Installing the ConsoleRemoving the access cover from the P80 console To thread the cable assemblyLocation Connecting Cables P80To connect the television cable Connecting the Television CableCable Connector Type Circuit Location Connecting the television cable Connecting the Ethernet and Base Unit Data CablesConnecting the Power Cable Connecting the Heart Rate Sensor CableTo complete the installation Completing the Console Installation P80Threading the Cable Assembly P30 and P20 Console positioning on base unit Connecting Cables P30 Connecting Cables P20 To verify that the heart rate display is operational Completing the Console Installation P30 and P20Verifying That the Heart Rate Display Is Operational Page Daily Cleaning MaintenanceDaily Inspection Storing the Chest Strap Quarterly MaintenanceTo perform quarterly maintenance To move the exercise bike Moving the EquipmentLong-Term Storage Rate of Motion Self-Powered FeaturesMinimum requirements for operation Informational Displays Prior to Shutdown Symptoms of a Low BatteryOptional Power Adapter Kit Using the Optional Power AdapterReplacing the Battery Warranty Periods and Coverage Commercial Cardiovascular Equipment Limited WarrantyLimited Warranty Conditions and Restrictions Exclusive Remedies Complete this portion and keep for your records Exclusion of Consequential and Incidental DamagesCommercial Cardiovascular Equipment Limited Warranty Page Page Precor Incorporated Operating and Maintaining the P30 Console Page Page Edition Information Important Safety Instructions Operating and Maintaining the P30 Console  Do not lean on or pull on the console at any time Hazardous Materials and Proper Disposal Regulatory Notices for Cardiovascular Exercise Equipment 240 V Equipment Designated for U.S. Markets 240-volt, 20-amp power plug 120-volt, 20-amp power plugOperating and Maintaining the P30 Console 240 V Equipment Designated Operating and Maintaining the P30 Console Getting Started Activating the Console for Self-Powered EquipmentActivating the Console for Self-Powered Equipment Optional Use of the Power Adapter Identifying Parts of the Console Number Part Name Details Watts Number Part Name Details System Settings Setting Up the Console5 1 5 6 To view the Club Parameters settingsNavigational keys for the system setting modes Key Set Units All Equipment Setting Club Parameter ValuesSafety Code Treadmill only Select Language All EquipmentSet Cool Down Time All Equipment Set Max Workout Time All EquipmentSet Max Pause Time All Equipment Custom Program keys Equipment Key Name Description Creating a Custom WorkoutValue Range on or OFF To create a custom programHidden Programs Treadmill only Set Speed Limit Treadmill onlySet Incline Limit Treadmill only Value Range 0 to Set Resistance Range Bike onlySet Crossramp Auto Level EFX Dual only Value Information provided To view the System settingsViewing the Informational Displays Informational Displays valuesProduct Value Information provided Event LogEvent Description of Event Number User ID Entry with Csafe Equipment Csafe access keys Keys FunctionOperating and Maintaining the P30 Console Introducing Users to the P30 Console Using the Touch Heart Rate FeatureHeart rate target zones Heart rate strap Using a Chest Strap TransmitterTo use a chest strap transmitter Interfere with pacemakers or otherRestart switch Using the Treadmill Safety ClipAttaching the safety clip Treadmill Auto Stop Automatic Stop Function WORKOUT, Press QUICKSTART, or Enter to Begin Starting a WorkoutTo choose a workout goal before you begin exercising Starting a Preset Programmed WorkoutSetting Options To choose a language setting before you begin exercisingTo choose a unit of measure before you begin exercising Setting Options after You Begin a WorkoutTo enter your Age and Weight during a workout Pending Shutdown Self-Powered Equipment Pausing and Resuming an Exercise SessionPaused Externally Powered Equipment Ending a Session Operating and Maintaining the P30 Console Interval ProgramsManual Heart RatePerformance Weight LossVariety To remove dust and dirt from the console Cleaning the Console and Display20031 142nd Avenue NE January Box Woodinville, WA USA