ProForm PFTL49609.0 user manual Top, Problem The walking belt slows when walked on

Page 23
Idler Roller Bolts
2–3 in.

Remove the three #8 x 3/4" Screws (12) and care-

 

12

fully pivot the Motor Hood (59) off.

59

 

 

Locate the Reed Switch (72) and the Magnet (45)

 

 

on the left side of the Pulley (46). Turn the Pulley

 

 

until the Magnet is aligned with the Reed Switch.

 

 

Make sure that the gap between the Magnet and

1/8 in.

 

the Reed Switch is about 1/8 in. (3 mm). If nec-

 

essary, loosen the #8 x 3/4" Truss Head Screw

72

45

(17), move the Reed Switch slightly, and then

retighten the Screw. Reattach the Motor Hood (not

 

46

shown) with the #8 x 3/4" Screws (not shown).

 

 

Reattach the Belly Pan Screws (not shown) if nec-

Top

 

essary. Run the treadmill for a few minutes to

 

check for a correct speed reading.

View

 

PROBLEM: The incline of the treadmill does not change correctly

SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re- move the key. After a few seconds, re-insert the key. The treadmill will automatically rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 13.

b. If the walking belt is overtightened, treadmill perfor- b mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG

THE POWER CORD. Using the hex key, turn both idler roller bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walk- ing belt is properly tightened.

c. If the walking belt still slows when walked on, see the front cover of this manual.

23

Image 23
Contents On the WEB QUESTIONS?Model No. PFTL49609.0 Serial No Mon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MTTable of Contents Important Precautions Page Before YOU Begin Assembly Wheel must turn freely Page Wheel must turn freely Firmly tighten the Bolts Nected PROPERLY, the Console MAY Again. if the Connectors are not CONBe Damaged When YOU Turn on 109, 110. Make sure that the wires are notMake sure that no wires are pinched PRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Console DiagramStart the walking belt HOW to Turn on the PowerHOW to USE the Manual Mode Insert the key into the consoleMeasure your heart rate if desired Select a calorie goal workout HOW to USE the Weight Loss CenterHOW to USE a Classic Workout Optional Chest Pulse Sensor HOW to USE the Stereo Sound SystemInformation Mode HOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Lower the Treadmill for USE Compatible with GFCI-equipped outlets TroubleshootingProblem The power turns off during use Top Problem The walking belt slows when walked onProblem Solution Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesKey No. Qty Description Part LIST-Model No. PFTL49609.0Qty Exploded Drawing A-Model No. PFTL49609.0 R0310A Exploded Drawing B-Model No. PFTL49609.0 Exploded Drawing C-Model No. PFTL49609.0 R0310A Exploded Drawing D-Model No. PFTL49609.0 R0310A Icon Health & Fitness, Inc., 1500 S W., Logan, UT Ordering Replacement PartsLimited Warranty