Agilent Technologies 5203 manual Regulatory Compliance Table, Feature Test Method Performance

Page 10

10

– TRANSMITTER OUTPUT OPTICAL

SPECTRAL WIDTH (FWHM) –nm

Δλ

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

 

180

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

160

 

 

 

 

 

 

 

 

 

 

 

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140

 

 

 

 

 

 

 

 

 

 

 

 

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

 

 

tr/f – TRANSMITTER

 

 

120

 

 

 

 

OUTPUT OPTICAL

 

 

 

 

 

 

 

RISE/FALL TIMES –

ns

 

 

 

 

 

 

 

 

 

 

3.0

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

1260

1280

1300

1320

1340

1360

λC – TRANSMITTER OUTPUT OPTICAL

CENTER WAVELENGTH –nm

HFBR-5205 TRANSMITTER TEST RESULTS

OF λC, Δλ AND tr/f ARE CORRELATED AND

COMPLY WITH THE ALLOWED SPECTRAL WIDTH AS A FUNCTION OF CENTER WAVELENGTH FOR VARIOUS RISE AND FALL TIMES.

RELATIVE INPUT OPTICAL POWER (dB)

5

4

3

HFBR-5203/-5204/-5205

SERIES

2

1

0

-3

-2

-1

0

1

2

3

EYE SAMPLING TIME POSITION (ns)

CONDITIONS: 1.TA = 25° C

2.VCC = 5 Vdc

3.INPUT OPTICAL RISE/FALL TIMES = 1.0/2.1 ns.

4.INPUT OPTICAL POWER IS NORMALIZED TO CENTER OF DATA SYMBOL.

5.NOTE 16 AND 17 APPLY.

Figure 9. Transmitter Output Optical Spectral Width (FWHM) vs. Transmitter Output Optical Center Wavelength and Rise/Fall Times.

Figure 10. Relative Input Optical Power vs. Eye Sampling Time Position.

Regulatory Compliance Table

Feature

Test Method

Performance

 

 

 

Electrostatic Discharge

MIL-STD-883C

Meets Class 2 (2000 to 3999 Volts)

(ESD) to the Electrical

Method 3015.4

Withstand up to 2200 V applied between electrical

Pins

 

pins.

Electrostatic Discharge

Variation of

Typically withstand at least 25 kV without damage

(ESD) to the Duplex SC

IEC 801-2

when the Duplex SC Connector Receptacle

Receptacle

 

is contacted by a Human Body Model probe.

Electromagnetic

FCC Class B

Transceivers typically provide a 13 dB margin

Interference (EMI)

CENELEC EN55022

(with duplex SC receptacle) or a 9 dB margin

 

Class B (CISPR 22B)

(with duplex ST receptacles) to the noted

 

VCCI Class 2

standard limits when tested at a certified test

 

 

range with the transceiver mounted to a circuit

 

 

card without a chassis enclosure.

Immunity

Variation of IEC 801-3

Typically show no measurable effect from a

 

 

10 V/m field swept from 10 to 450 MHz applied

 

 

to the transceiver when mounted to a circuit card

 

 

without a chassis enclosure.

Image 10
Contents Applications DescriptionReceiver Sections Application InformationPackage ST Block Diagram ST Package Outline Drawing Optical Power Budget vs. Fiber Optic Cable Length Solder and Wash Process Compatibility Recommended Handling PrecautionsTransceiver Jitter Performance Shipping ContainerBoard Layout Decoupling Circuit and Ground Planes Recommended Decoupling and Termination CircuitsRegulatory Compliance Recommended Board Layout Hole PatternElectromagnetic Interference EMI ImmunityFeature Test Method Performance Regulatory Compliance TableApplications Support Materials Transceiver Reliability Performance Qualification DataOrdering Information Evaluation KitsParameter Symbol Min Typ Max Unit Reference HFBR-5203, -5204, and -5205 Series Absolute Maximum RatingsSupply Current Page HFBR-5203/-5203T HFBR-5204/-5204T HFBR-5205/-5205T PA PD