HFBR-5205/-5205T

Receiver Optical and Electrical Characteristics (TA = 0°C to 70°C, VCC = 4.75 V to 5.25 V)

Parameter

Symbol

Min.

Typ.

Max.

Unit

Reference

Input Optical Power

PIN Min. (W)

 

 

-30

dBm avg.

Note 16

Minimum at Window Edge

 

 

 

 

 

Figure 10

Input Optical Power

PIN Min. (C)

 

 

-31

dBm avg.

Note 17

Minimum at Eye Center

 

 

 

 

 

Figure 10

Input Optical Power Maximum

PIN Max.

-14

 

 

dBm avg.

Note 16

Operating Wavelength

λ

1260

 

1360

nm

 

Systematic Jitter Contributed

SJ

 

0.2

1.2

ns p-p

Note 18

by the Receiver

 

 

 

 

 

 

Random Jitter Contributed

RJ

 

1

1.91

ns p-p

Note 19

by the Receiver

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal Detect - Asserted

PA

PD + 1.5 dB

 

-31

dBm avg.

Note 20

Signal Detect - Deasserted

PD

-45

 

 

dBm avg.

Note 21

Signal Detect - Hysteresis

PA - PD

1.5

 

 

dB

 

Signal Detect Assert Time

 

0

55

100

μs

Note 22

(off to on)

 

 

 

 

 

 

Signal Detect Deassert Time

 

0

110

350

μs

Note 23

(on to off)

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.This is the maximum voltage that can be applied across the Differential Transmitter Data Inputs to prevent damage to the input ESD protection circuit.

2.The outputs are terminated with

50 Ω connected to VCC -2 V.

3.The power supply current needed to operate the transmitter is provided to differential ECL circuitry. This circuitry maintains a nearly con- stant current flow from the power supply. Constant current operation helps to prevent unwanted electrical noise from being generated and conducted or emitted to neighboring circuitry.

4.This value is measured with the outputs terminated into 50 Ω

connected to VCC -2 V and an Input Optical Power level of -14 dBm average.

5.The power dissipation value is the power dissipated in the receiver itself. Power dissipation is calcu- lated as the sum of the products of supply voltage and currents, minus

the sum of the products of the output voltagesandcurrents.

6.This value is measured with respect

to VCC with the output terminated into 50 Ω connected to VCC -2 V.

7.The output rise and fall times are measured between 20% and 80% levels with the output connected to

VCC -2 V through 50 Ω.

8.These optical power values are measured with the following conditions:

The Beginning of Life (BOL) to the End of Life (EOL) optical power degradation is typically

1.5 dB per the industry conven- tion for long wavelength LEDs. The actual degradation observed in Agilent’s 1300 nm LED products is <1 dB, as specified in this datasheet.

Over the specified operating voltage andtemperatureranges.

With 25 MBd (12.5 MHz square- wave) input signal.

At the end of one meter of noted optical fiber with cladding modes removed.

The average power value can be converted to a peak power value by adding 3 dB. Higher output optical powertransmittersareavailableon specialrequest.

9.The same comments of note 9 apply except that industry convention for short wavelength LED (800 nm) aging is 3 dB. This value for Output Optical Power will provide a minimum 6 dB optical power budget at the EOL, which will provide at least 150 meter link lengths with margin left over for overcoming normal passive losses, such as in- line connectors, in the cable plant. The actual degradation observed in normal commercial environments will be considerably less than this amount with Agilent’s 800 nm LED products. Please consult with your local Agilent sales representative for furtherdetails.

10.The Extinction Ratio is a measure of the modulation depth of the optical signal. The data “0” output optical power is compared to the data “1” peak output optical power and

Image 18
Contents Applications DescriptionApplication Information Receiver SectionsPackage ST Block Diagram ST Package Outline Drawing Optical Power Budget vs. Fiber Optic Cable Length Solder and Wash Process Compatibility Recommended Handling PrecautionsTransceiver Jitter Performance Shipping ContainerBoard Layout Decoupling Circuit and Ground Planes Recommended Decoupling and Termination CircuitsRegulatory Compliance Recommended Board Layout Hole PatternElectromagnetic Interference EMI ImmunityFeature Test Method Performance Regulatory Compliance TableApplications Support Materials Transceiver Reliability Performance Qualification DataOrdering Information Evaluation KitsParameter Symbol Min Typ Max Unit Reference HFBR-5203, -5204, and -5205 Series Absolute Maximum RatingsSupply Current Page HFBR-5203/-5203T HFBR-5204/-5204T HFBR-5205/-5205T PA PD