Weider WESY19510 user manual TROUBLE-SHOOTING and Maintenance, Tightening the Cables

Page 19

TROUBLE-SHOOTING AND MAINTENANCE

Inspect and tighten all parts each time you use the weight system. Replace any worn parts immediately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cables before resistance is felt, the cables should be tightened. Slack can be removed from the cables by tightening the 1/4” Nylon Locknuts (2) at the end of the Long Cable (23) (see A, inset drawing) and at the end of the Short Cable

(58)(see B, inset drawing). To do this you may need to remove the Small “U”-Bracket (67) from the Weight Tube (63) or remove the 3 1/2” Pulley (15) from the Long “U”-Bracket (57). Make sure that the cables are not too tight, or the Top Weight (76) will be lifted off the weight stack.

Additional slack can be removed by moving the 3 1/2” Pulley (15) to the lower hole in the Long “U”-Bracket (57). Remove the 3/8” Nylon Locknut (21) and the 3/8” x 2” Bolt (12) from the Cable Trap (66), Pulley, and “U”-Bracket. Re-attach the Pulley and Cable Trap. Be sure that the Cable Trap is positioned to hold the Cable in place, and that the Cable and Pulley move smoothly.

Note: If a cable tends to slip off the pulleys often, the cable may have become twisted. Remove the cable and re-install it.

If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.

A

 

 

23

63

67

76

 

 

23

 

2

 

67

B

 

23

15

 

66

57

 

21

12

 

2

58

19

Image 19
Contents Model No. WESY19510 Serial No QUESTIONS?Table of Contents Decal Decal. Apply the decal in the location shown Important PrecautionsBefore YOU Begin Frame Assembly AssemblyMake Things Easier for Yourself Locknuts yet WeightsTighten the Nylon Locknuts used in steps Weight Guides are at the top, as shown Arm AssemblyLocknut the Press Frame must be able to pivot freely Sure that the upper end of the Right Arm is Arm. Arm identification is very important for StepBehind the indicated bracket on the Top Frame Cable Assembly Page Inset shows view Locate the Short Cable 58. Lay the ShortFrom other side Inset shows view Seat Assembly Page Page Changing the Weight Setting AdjustmentsAttaching the LEG Lever to the LOW Pulley Station Weight Resistance Chart Tightening the Cables TROUBLE-SHOOTING and MaintenanceLong Cable 23 TOP View Cable DiagramShort Cable Page Key No. Qty Description Part LIST-Model No. WESY19510Exploded DRAWING-Model No. WESY19510 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT Remove this Part Identification Chart from the Manual Part Identification CHART-Model No. WESY19510 R1101A