Weider WESY75741 user manual Troubleshooting, Recalibrating the Console, Cleaning the BAR Guides

Page 19

TROUBLESHOOTING

RECALIBRATING THE CONSOLE

To recalibrate the Console (67), first plug in the resist- ance system (see PLUGGING IN THE RESISTANCE SYSTEM on page 16). Then, press and hold the NEXT button and the MOTORIZED WEIGHT ADJUSTMENT + button for five seconds. When the buttons are released, a number will appear in the REPS display. Press the NEXT button again, and then press the MOTORIZED WEIGHT ADJUSTMENT + button; this will start the recalibration process. This may take a few minutes as the motor moves between the lowest and highest resistance settings. When the motor finishes, unplug the transformer from the 120- volt outlet.

The Console (67) will be recalibrated. Use the resist- ance system as described in the CONSOLE OPERA- TION section, starting on page 16.

CLEANING THE BAR GUIDES

Over time, dust may build up on the Crossbar Guides (15), causing a squeaking noise as the resistance system is used. If this occurs, wipe off the Crossbar Guides with a damp cloth and a mild, non-abrasive detergent. Do not use solvents.

ADJUSTING THE RESISTANCE

When the resistance setting changes, the motor will be heard. To prevent damage to the motor, do not pull any of the cables while the resistance setting is changing. If a cable is pulled, the words

RELEASE HANDLES AND READJUST RESIST- ANCE AS DESIRED may appear in the main display on the console.

If this message is displayed repeatedly but no cable is being pulled, there may be too much tension on the Upper Cable (115). Adjust the tension as described below.

To decrease the tension on the Upper Cable (115), turn the two 3/8” x 38mm Tension Screws (59) twice, counterclockwise. Select the desired resistance set- ting. Repeat this step if necessary.

See UPPER CABLE ADJUSTMENT on page 12 to ensure proper cable tension adjustment.

67

15

115

59

19

Image 19
Contents Model No. WESY75741 Serial No QUESTIONS?Customer HOT Line Table of Contents Keep hands and fingers clear of this area Important Precautions Before YOU Begin Make Things Easier for Yourself AssemblyTighten the 1/2 x 25mm Screw Push the excess Upper Wire Harness 71 into the Upright Do not tighten the Bolt yet Do not tighten the Locknut yetPage Page Upper Cable Adjustment Attaching the High Pulleys AdjustmentsRemove the high pulleys when not in use Using the LEG LeverAttaching the Squat Station Attaching the AccessoriesAdjusting the Backrest Cable in the same mannerAdjusting the Seat Adjusting the Squat ARMStoring the Resistance System Manual Operation Features of the ConsoleConsole Operation Plugging in the Resistance SystemProgram Operation Upper Cable Cable DiagramRecalibrating the Console TroubleshootingCleaning the BAR Guides Adjusting the ResistanceExercise Guidelines Cooling Down Muscle ChartStaying Motivated Thursday Aerobic Exercise Date Exercise Weight Sets RepsDate Aerobic ExerciseMonday Part Identification CHART-Model No. WESY75741 Key Qty Description Part LIST-Model No. WESY75741R0404A Exploded DRAWING-Model WESY75741Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT