WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building, or area of all occupants.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

INSTALLATION INSTRUCTIONS

Tools andParts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Parts supplied:

Remove parts package from dryer drum. Check that all parts were included.

8" or 10" pipe wrench

8" or 10" adjustable wrench (for gas connections)

Flat-blade screwdriver

Adjustable wrench that opens to 1" (2.5 cm) or hex-head socket wrench (for adjusting dryer feet)

¼" nut driver or socket wrench (recommended)

Level

Knife

Vent clamps

Pipe-joint compound resistant to LP gas

Caulking gun and compound (for installing new exhaust vent)

Pliers

Tape measure

4 leveling legs

Parts needed:

Check local codes and consult gas supplier. Check existing gas supply, electrical supply and venting, and read “Electrical Requirements,” “Gas Supply Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require special parts (listed following) that may be ordered by calling the dealer from whom you purchased your dryer. For further information, please reference the front page of the Dryer User Instructions.

Mobile Home Installation Kit. Ask for Part Number 346764.

Metal exhaust system hardware.

2

Image 2
Contents Instructions D’INSTALLATION DE LA Sécheuse Dryer SafetyParts supplied Installation InstructionsTools andParts Parts neededLocationRequirements Dryer DimensionsInstallation Clearances You will needElectrical Requirements Mobile Home Additional Installation RequirementsMobile home installations require Gas SupplyRequirementsVent material Gas supply pressure testingVentingRequirements Recommended exhaust installations PlanVentSystemVent system chart Install VentSystemInstall LevelingLegs Special provisions for mobile home installationsLevelDryer MakeGasConnectionConnectVent For mobile home useReversible Super Wide Side-Swing Door ReverseDoorSwingOptionalReversible Large Side-Swing Door CompleteInstallation If the dryer will not start, check the followingSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteOutillageetpièces nécessaires Instructions D’INSTALLATIONExigencesd’installation ’installation dans une maison mobile exige Espacements d’installationDimensions de la sécheuse Spécifications électriquesExigences concernant le raccordement au gaz Spécifications delalimentation en gazCanalisation d’arrivée de gaz Exigencesconcernantlévacuation Matériel pour lévacuationBrides de serrage Installations d’évacuation recommandéesPlanificationdusystèmed’évacuation ÉvacuationDéterminer litinéraire dacheminement du conduit Installationdu systèmed’évacuationInstallationdespieds denivellement Tableau des systèmes dévacuationMiseàniveau dela sécheuse RaccordementaugazRaccordementduconduitd’évacuation Pour utilisation dans une maison mobilePorte réversible extra-large à pivotement latéral InversiondusensdouverturedelaportefacultatifGrande porte réversible à pivotement latéral W10150630A SP PN W10150631A Acheverl’installationSi la sécheuse ne démarre pas, vérifier ce qui suit