Whirlpool W10150630A LocationRequirements, Dryer Dimensions, You will need

Page 3

LocationRequirements

WARNING

Dryer Dimensions

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. A gas

 

dryer must be exhausted to the outdoors. See “Venting

 

Requirements.”

A grounded electrical outlet located within 2 ft (61 cm) of

43³⁄₈"

(110cm)

*26" (66cm)

43³⁄₈"

(110cm)

*27¾"

(70.5cm)

15¼"

(38.74cm) 43³⁄₈" (110cm)

*27¾"

(70.5cm)

29"

(73.66cm)

A

22¾"

(57.8cm) 43³⁄₈"

(110cm)

*27¾"

(70.5cm)

29"

(73.66cm)

22¾"

(57.8cm)

29"

(73.66cm)

B

13¾" (34.9cm)

29"

(73.66cm)

either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the dryer and a total weight (dryer

and load) of 200 lbs (90.7 kg). The combined weight of a

companion appliance should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. (If slope is greater than 1" [2.5 cm], install Extended

Dryer Feet kit, Part No. 279810.) Clothes may not tumble

properly and models with automatic sensor cycles may not

operate correctly if dryer is not level.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

CD

A. Small Opening Side-Swing Door

B. Large Opening Side-Swing Door

C. Wide Opening Side-Swing Door

D. Wide Opening Hamper Door

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

 

 

 

 

 

 

 

3"*

 

 

 

 

14" max.*

 

(7.6 cm)

 

 

 

 

48 in.2 *

 

 

 

 

 

(35.6cm)

 

18"*

 

 

 

 

 

(310 cm2 )

 

 

 

 

 

 

 

 

(45.7 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

24 in.2 *

3"*

 

 

 

 

 

 

(155 cm2 )

(7.6 cm)

1"

29"

1"

1"*

27¾"

5"*

 

 

(2.5 cm)

(73.66 cm)

(2.5 cm)

(2.5 cm)

(70.5 cm)

(12.7 cm)

 

 

A

 

 

B

 

 

C

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

3

Image 3
Contents Dryer Safety Instructions D’INSTALLATION DE LA SécheuseParts needed Installation InstructionsTools andParts Parts suppliedYou will need Dryer DimensionsInstallation Clearances LocationRequirementsGas SupplyRequirements Mobile Home Additional Installation RequirementsMobile home installations require Electrical RequirementsGas supply pressure testing VentingRequirementsVent material PlanVentSystem Recommended exhaust installationsSpecial provisions for mobile home installations Install VentSystemInstall LevelingLegs Vent system chartFor mobile home use MakeGasConnectionConnectVent LevelDryerReverseDoorSwingOptional Reversible Large Side-Swing DoorReversible Super Wide Side-Swing Door If the dryer will not start, check the following CompleteInstallationVotre sécurité et celle des autres est très importante Sécurité DE LA SécheuseInstructions D’INSTALLATION Exigencesd’installationOutillageetpièces nécessaires Spécifications électriques Espacements d’installationDimensions de la sécheuse ’installation dans une maison mobile exigeSpécifications delalimentation en gaz Canalisation d’arrivée de gazExigences concernant le raccordement au gaz Matériel pour lévacuation ExigencesconcernantlévacuationÉvacuation Installations d’évacuation recommandéesPlanificationdusystèmed’évacuation Brides de serrageTableau des systèmes dévacuation Installationdu systèmed’évacuationInstallationdespieds denivellement Déterminer litinéraire dacheminement du conduitPour utilisation dans une maison mobile RaccordementaugazRaccordementduconduitd’évacuation Miseàniveau dela sécheuseInversiondusensdouverturedelaportefacultatif Grande porte réversible à pivotement latéralPorte réversible extra-large à pivotement latéral Acheverl’installation Si la sécheuse ne démarre pas, vérifier ce qui suitW10150630A SP PN W10150631A