3.Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.
1 | 4 |
| |
2 |
|
| 5 |
3 | 6 |
|
1.External ground conductor screw
2.Green or bare copper wire of power supply cord
3.³⁄₄ in. (1.9 cm) UL listed strain relief
4.Center
5.Neutral grounding wire (green/yellow)
6.Neutral wire (white or center wire)
4.Place the hooked end of the neutral wire (white wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
5.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
2.Connect neutral wire (white or center wire) of power supply cord to the center,
1 | 3 |
2 | 4 |
| 5 |
1.External ground conductor screw
2.Neutral grounding wire (green/yellow)
3.Center
4.Neutral wire (white or center wire)
5.³⁄₄ in. (1.9 cm) UL listed strain relief
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
6.Tighten strain relief screws.
7.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
3-wire connection: Power supply cord
Use where local codes permit connecting
2 | 4 | 5 |
1
3 | 7 | 6 |
1.
2.
3.Neutral prong
4.Spade terminals with up turned ends
5.³⁄₄ in. (1.9 cm) UL listed strain relief
6.Ring terminals
7.Neutral (white or center wire)
1.Loosen or remove center terminal block screw.
3-wire connection: Direct wire
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 3¹⁄₂ in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in. (2.5 cm). If using
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw. See example below.
1.Loosen or remove center terminal block screw.
10