Minimum installation spacing for recessed or closet installation, with or without a pedestal
■The dimensions shown are for the minimum spacing allowed.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Closet installation - Dryer only
Minimum installation spacing for cabinet installation
■The dimensions shown are for the minimum spacing allowed.
■For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.
7" (17.8 cm) | 7" (17.8 cm) |
|
| " |
|
| " |
" | ½" | " |
| 1 |
|
"
in.
in.
"
2
9"
(22.9 cm)
0" | 31¹ " | 0" | 0" | 27" | 0" |
(0 cm) | (80.0 cm) | (0 cm) (0 cm) | (68.6 cm) | (0 cm) |
1.Side view - closet or confined area
2.Closet door with vents
Recessed or closet installation - Dryer on pedestal
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The install- ation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24,
1 |
½ |
2 |
HUD Part 280) or Standard
Mobile home installations require:
■Metal exhaust system hardware which is available for purchase from your dealer.
■Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
1.Recessed area
2.Side view - closet or confined area