Whirlpool 8533582 manual Location Requirements, Installation clearances, Dryer Dimensions

Page 5

Location Requirements

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30 amp circuit.

A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. If slope is greater than 1 in. (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18 in. (46 cm) above the floor. If using a pedestal, you will need an additional 6 in. (15.24 cm).

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to fully open the dryer door.

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.

Companion appliance spacing should also be considered.

Dryer Dimensions

½

* ½

*Most installations require a minimum 5½ in. (14 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Minimum installation spacing for custom undercounter installation

The dimensions shown are for the minimum spacing allowed.

Custom undercounter installation - Dryer only

5

Image 5
Contents 8533582 Electronic Electric DryerUse & Care Guide Table of Contents Your safety and the safety of others are very important Dryer SafetyOptions Installation InstructionsToolsandParts Dryer Dimensions Installation clearancesCustom undercounter installation Dryer only Location RequirementsMobile home Additional installation requirements Minimum installation spacing for cabinet installationMobile home installations require Closet installation Dryer onlyElectrical Connection Electrical RequirementsIt is your responsibility Electrical Connection Wire connection Direct wire Wire connection Power supply cordLoosen or remove center terminal block screw Venting Requirements Optional 3-wire connectionOptional exhaust installations Typical exhaust installationsAlternate installations for close clearances Plan Vent SystemDetermine Vent Length Install VentSystemSpecial provisions for mobile home installations Complete Installation Install Leveling LegsLevel Dryer Connect VentTo use an Automatic Cycle Dryer USEStartingYour Dryer Stopping YourDryer Pausingor RestartingControl Locked LoadingStatusLights Drying and Cycle TipsCycles Drying Rack Additional FeaturesCleaning the Lint Screen Cleaning the Dryer LocationEvery load cleaning Dryer CareRemoving AccumulatedLint Cleaningthe Dryer InteriorVacation and Moving Care Changingthe Drum LightTroubleshooting For assistance and service If you need replacement partsAccessories U.S.A Items shrinking8533582 Whirlpool Corporation will not pay for