Electrical Connection Options
If your home has: | And you will be | Go to Section |
| connecting to: |
|
A UL listed, 120/ | ||
(NEMA Type | 240 volt | Power supply cord |
| minimum, 30 |
|
| amp, dryer |
|
| power supply |
|
| cord* |
|
A fused | ||
| disconnect or | Direct Wire |
| circuit breaker |
|
(12.7 cm) | box* |
|
5" |
|
|
A UL listed, 120/ | ||
(NEMA type | 240 volt | Power supply cord |
| minimum, 30 |
|
| amp., dryer |
|
| power supply |
|
| cord* |
|
A fused | ||
| disconnect or | Direct Wire |
3 1/2 " | circuit breaker |
|
box* |
| |
(8.9 cm) |
|
*If local codes do not permit the connection of a
4-wire connection: Power supply cord
IMPORTANT: A
2 | 6 |
1
3 | 4 | 5 | 7 |
1.
2.
3.Ground prong
4.Neutral prong
5.Spade terminals with upturned ends
6.¾ in. (1.9 cm) UL listed strain relief
7.Ring terminals
1.Remove center terminal block screw.
2.Remove appliance ground wire (green with yellow stripes) from external ground conductor screw. Fasten it under center,
1 | 2 |
3
1.External ground conductor screw - Dotted line shows position of NEUTRAL ground wirebefore being moved to center terminalblock screw
2.Center
3.Green/yellow wire of harness
3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
4.Connect neutral wire (white or center wire) of power supply cord under center screw of the terminal block.
1 | 4 |
2
3 | 5 |
6
1.External ground conductor screw
2.Green or bare copper wire of power supply cord
3.³⁄₄ in. (1.9 cm) UL listed strain relief
4.Center
5.Neutral grounding wire (green/yellow)
6.Neutral wire (white or center wire)
5.Connect the other wires to outer terminal block screws. Tighten screws.
6.Tighten strain relief screws.
7.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
4-wire connection: Direct wire
IMPORTANT: A
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5 in. (12.7 cm). Cut 1¹⁄₂ in. (3.8 cm) from 3 remaining wires. Strip insulation back 1 in. (2.5 cm). Shape ends of wires into a hook shape.
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw. See example below.
1.Remove center terminal block screw.
2.Remove appliance ground wire (green with yellow stripes) from external ground conductor screw. Fasten it under center,
9