Whirlpool 8533582 manual Install VentSystem, Special provisions for mobile home installations

Page 13

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section of this manual to order.

Over the top Installation: Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0 in. (0 cm) to 18 in. (45.72 cm) mismatch

Part Number 4396011 - 18 in. (45.72 cm) to 29 in. (73.66 cm) mismatch

Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine Vent Length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90º turns.

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

2

1

4"

(10.2 cm)

4" (10.2 cm)

1.Louvered hood style

2.Box hood style

The angled hood style (shown following) is acceptable.

4" (10.2 cm)

2½"

(6.4 cm)

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

3.Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than those specified in the Vent Length Chart.

The following chart helps you determine your maximum vent length based on the number of 90° turns or elbows you will need and the type of vent (rigid or flexible metal) and hood that you will use.

Vent Length Chart

Number of

Type of

Box or

Angled

90º turns

vent

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Install VentSystem

1.(Optional) Put on safety glasses and gloves.

2.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

3.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp.

4.Run vent to dryer location. Use the straightest path possible. See “Determine Vent Length.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

13

Image 13
Contents Use & Care Guide Electronic Electric Dryer8533582 Table of Contents Your safety and the safety of others are very important Dryer SafetyToolsandParts Installation InstructionsOptions Dryer Dimensions Installation clearancesCustom undercounter installation Dryer only Location RequirementsMobile home Additional installation requirements Minimum installation spacing for cabinet installationMobile home installations require Closet installation Dryer onlyIt is your responsibility Electrical RequirementsElectrical Connection Electrical Connection Wire connection Direct wire Wire connection Power supply cordLoosen or remove center terminal block screw Venting Requirements Optional 3-wire connectionOptional exhaust installations Typical exhaust installationsAlternate installations for close clearances Plan Vent SystemSpecial provisions for mobile home installations Install VentSystemDetermine Vent Length Complete Installation Install Leveling LegsLevel Dryer Connect VentStartingYour Dryer Dryer USETo use an Automatic Cycle Stopping YourDryer Pausingor RestartingControl Locked LoadingStatusLights Drying and Cycle TipsCycles Drying Rack Additional FeaturesCleaning the Lint Screen Cleaning the Dryer LocationEvery load cleaning Dryer CareRemoving AccumulatedLint Cleaningthe Dryer InteriorVacation and Moving Care Changingthe Drum LightTroubleshooting For assistance and service If you need replacement partsAccessories U.S.A Items shrinking8533582 Whirlpool Corporation will not pay for