Alliance Laundry Systems WFF135, WFF75, WFF100, WFF65, WFF165 instruction manual Liters / 18 pounds

Page 36

4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications WFF75, IWF074, IWF018, CWF074, CWF018

75 liters / 18 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker (US- market)

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

 

NON-US

 

N

440-480

50/60

3

3+PE

3

10

10

14/2.5

 

12

15

 

16

14/2.5

P

380-415

50/60

3

3+N+PE

7

15

16

14/2.5

3x2 kW

16

20

 

20

12/4.0

Q

200-240

50/60

3

3+PE

7

15

16

14/2.5

23

30

 

32

10/6.0

 

 

X

200-240

50/60

1/3

2/3+PE

7

15

16

14/2.5

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x1.4 kW

13

15

 

16

14/2.5

Q

200-240

50/60

3

3+PE

 

 

 

 

18

20

 

20

12/4.0

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x3 kW

21

30

 

32

10/6.0

Q

200-240

50/60

3

3+PE

 

 

 

 

30

40

 

40

8/10.0

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

20

30

 

25

10/6.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x4 kW

24

30

 

30

10/6.0

Q

200-240

50/60

3

3+PE

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

Table 3

 

 

 

 

 

 

 

36

Image 36
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers WFF65 WFF75Page Page Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data WFF65, IWF065, IWF014, CWF065, CWF014Dimensions WFF65, IWF065, IWF014, CWF065, CWF014 Technical data WFF75, IWF074, IWF018, CWF074, CWF018 Dimensions WFF75, IWF074, IWF018, CWF074, CWF018 Technical data WFF100, IWF100, IWF025, CWF100, CWF025 Dimensions WFF100, IWF100, IWF025, CWF100, CWF025 Technical data WFF135, IWF135, IWF030, CWF135, CWF030 Dimensions WFF135, IWF135, IWF030, CWF135, CWF030 Technical data WFF165, IWF165, CWF165 Dimensions WFF165, IWF165, CWF165 Installation and Connection Instructions SurfaceAnchoring on a metal base Directly on the ground273 560 645 287 550 660 233 560 645.1 327 550 660 233 660 29.33 16.81 745 427 550 260 670 731 410 640 780 260 770 831 510 640 780 Water connection Water drainElectrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 18 pounds Liters / 25 pounds Liters / 30 pounds Electrical Specifications WFF165, IWF165, CWF165 Liters / 35 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceAnnual maintenance WFF100WFF135 WFF165Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service