Alliance Laundry Systems WFF65, WFF75, WFF135, WFF100, WFF165 instruction manual Steam connection

Page 43

Steam connection

5

WARNING

Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched.

Machines with steam heating must have a steam valve between the steam installation and the machine.

5

3

4

3

2

1

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

With direct steam injection into the machine (See Table 7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Steam pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Steam cut-off valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Pipe coupling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Steam filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Magnetic steam valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6.

Curve MF

 

 

 

 

 

 

 

 

 

 

 

 

7.

Steam hose with appropriate pipe coupling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam Supply Information

 

 

 

 

 

 

 

 

 

MODEL

 

 

inletSteam connection,inch

Numberof inletssteam

Recommended pressure,bar

Recommended pressure,psi

Maximum pressure,bar

Maximum pressure,psi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the WFF65 = WFF65, IWF065, IWF014, CWF065, CWF014

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WFF75 = WFF75, IWF074, IWF018, CWF074, CWF018

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WFF100 = WFF100, IWF100, IWF025, CWF100, CWF025

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WFF135 = WFF135, IWF135, IWF030, CWF135, CWF030

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WFF165 = WFF165, IWF165, CWF165

3/8

1

2.0 - 5.5

30 - 80

5.5

80

Table 7

43

Image 43
Contents Washer Extractors Page Contents Internal connections of the electrical heating  WFF65 WFF75 Model NumbersPage Page Safety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data WFF65, IWF065, IWF014, CWF065, CWF014 Technical data and dimensionsDimensions WFF65, IWF065, IWF014, CWF065, CWF014 Technical data WFF75, IWF074, IWF018, CWF074, CWF018 Dimensions WFF75, IWF074, IWF018, CWF074, CWF018 Technical data WFF100, IWF100, IWF025, CWF100, CWF025 Dimensions WFF100, IWF100, IWF025, CWF100, CWF025 Technical data WFF135, IWF135, IWF030, CWF135, CWF030 Dimensions WFF135, IWF135, IWF030, CWF135, CWF030 Technical data WFF165, IWF165, CWF165 Dimensions WFF165, IWF165, CWF165 Directly on the ground Installation and Connection InstructionsSurface Anchoring on a metal base273 560 645 287 550 660 233 560 645.1 327 550 660 233 660 29.33 16.81 745 427 550 260 670 731 410 640 780 260 770 831 510 640 780 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Alternative Electric Heat Options Boiler Fed/Steam Heat Electric HeatLiters / 18 pounds Liters / 25 pounds Liters / 30 pounds Liters / 35 pounds Electrical Specifications WFF165, IWF165, CWF165Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineWFF165 Annual maintenanceWFF100 WFF135Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service