7

Annual maintenance

Belt tension:

Verify that the belts are running in the middle of the basket pulley.

Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).

Belt tension testing table

Model

Belt

Frequency (Hz)

Tension force (N)

Deflection (mm)

Deflection force

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at MIN

at MAX

 

 

 

MIN

MAX

MIN

MAX

tension

tension

MAX

WFF65

PJ8 1355

98

103

301

332

8,8

7,9

40

WFF75

PJ8 1355

98

103

301

332

8,8

7,9

40

WFF100

PJ8 1355

98

103

301

332

8,8

7,9

40

WFF135

PK7 1520

65

69

425

489

11,5

10,8

53

WFF165

PK7 1520

65

69

425

489

11,5

10,8

53

1 Deflection

2 Span length

46

Image 46
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers WFF65 WFF75Page Page Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data WFF65, IWF065, IWF014, CWF065, CWF014Dimensions WFF65, IWF065, IWF014, CWF065, CWF014 Technical data WFF75, IWF074, IWF018, CWF074, CWF018 Dimensions WFF75, IWF074, IWF018, CWF074, CWF018 Technical data WFF100, IWF100, IWF025, CWF100, CWF025 Dimensions WFF100, IWF100, IWF025, CWF100, CWF025 Technical data WFF135, IWF135, IWF030, CWF135, CWF030 Dimensions WFF135, IWF135, IWF030, CWF135, CWF030 Technical data WFF165, IWF165, CWF165 Dimensions WFF165, IWF165, CWF165 Anchoring on a metal base Installation and Connection InstructionsSurface Directly on the ground273 560 645 287 550 660 233 560 645.1 327 550 660 233 660 29.33 16.81 745 427 550 260 670 731 410 640 780 260 770 831 510 640 780 Water connection Water drainElectrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 18 pounds Liters / 25 pounds Liters / 30 pounds Electrical Specifications WFF165, IWF165, CWF165 Liters / 35 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceWFF135 Annual maintenanceWFF100 WFF165Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service