John Lewis JLWM1402 1400 instruction manual Electrical connection, Permanent connection

Page 25
- Earth
- Neutral - Live

SHOWER

 

 

 

SINK

TOILET

BATH

 

BIDET

WASHING

DISHWASHER

MACHINE

RAINWATER

 

 

'RUN-OFF'

 

 

 

 

FOUL DRAIN

SURFACE WATER

 

FOUL SEWERS

DRAINS & SEWERS

 

 

 

 

 

SEWAGE

UNTREATED

 

TREATMENT

DISCHARGE

 

WORKS

 

 

TREATED

 

 

DISCHARGE

RIVER

 

RIVER

 

 

P0987

 

 

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. The rating plate is located at the top of the rim of the open door.

 

Mod

 

Prod. No

P0042 BD

Ser. No

 

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363/A) fuse must be used.

Should the plug need to be replaced for any reason, proceed as described below.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow Blue

Brown

GREEN & YELLOW

E

 

13 A

N

L

 

BROWN

BLUE

 

 

CORD CLAMP

P1041

 

 

 

The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the earth symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal marked «N» or coloured black.

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

The power supply cable must be easily accessible after installing the appliance.

Important

If the mains supply cable is damaged it must be replaced; contact our warranty administrators on 0870 0107887 who will give you details for your local Service Force Centre.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

25

Image 25
Contents JLWM1201 Spin washing machine JLWM1402 Child Safety InstallationUse Contents Ecological hints Materials marked with the symbol are recyclableInterest Environment Machine works more economically if it is fully loadedDescription of the Appliance Child safety featureDoor locked light Detergent dispenser drawerProgramme selector dial Control PanelSpin button Option buttonsSelecting the delayed start Delay start buttonCancelling the delayed start Start/Pause buttonDisplay Programme phase indicator lightsFollowing pieces of information are shown on the display Programme information When the programme has finished, the End light comes onOperating Sequence Switch the machine onLoad the laundry Measure out the detergentHow to change an option or a programme during its cycle Select the Delay startSelect the spin speed or the None option Select the desired optionsEnd of programme How to interrupt a programmeLeave the door ajar in order to air the washing machine 1000g = 1 kg Washing HintsSheet Bath robeImportant Notes Wash Care SymbolsWashing programmes Programme Available Consumptions Off / ResetEnergy Water Time Description SoakMaintenance and Cleaning Emergency emptying out Cleaning the water inlet filterRemove any objects from the pump impeller by rotating it Screw the pump cover fully Close the pump doorSomething Not Working Spinning Machine vibrates whenDoor will not open Light has gone outTechnical Specifications Installation InstructionsUnpacking Installation on a Suspended FloorWater drainage Water inletAppliance must be connected to a cold water supply Into a drainage standpipeSpecial conditions LevellingInterest of the environment Onto a sink outlet spigotPermanent connection Electrical connection