Clearance Diagram- 30” Legacy Cooktop Model 3800
An appropriate exhaust hood with a minimum of 450 CFM is required on all 30" Legacy cooktops to ensure adequate and proper ventilation. For superior ventilation we recommend using a 36” hood, however a 30” hood is adequate.
L
M
J
G
H
K
N 1 N 2
I
O
Figure 2
Note: If cooktop must stand beside a refrigerator, it is
important for proper air circulation that there be at least 5” (13
cm) of space between the two appliances.
Note: Support deck must be able to
support a total weight of
4 burner model: 175 lbs
| Dim | 30" Legacy Cooktop |
|
|
|
| G | Maximum 25" (63cm) |
|
|
|
| H | Maximum 7 3/4" (21cm) |
|
|
|
| I | 30" (77 cm) |
|
|
|
| J | Minimum 6" (15cm) |
| left and right side | |
|
| |
|
|
|
| K | 13"(33cm) |
|
|
|
| L | Specify Width of Hood |
|
|
|
| M | 24" (61cm) |
|
|
|
| N1 | 30" min to 36" max |
|
| for standard and high back guard |
|
|
|
| N2 | 30" min to 32 "max |
| for low profile back guard | |
|
| |
|
|
|
Table 2 | O | 18" (45cm) |
|
|
4