Clearance Diagram- 36” Metro Cooktop Model 3825
An appropriate exhaust hood with a minimum of 900 CFM is required on all 36" Metro cooktops to ensure adequate and proper ventilation. For superior ventilation we recommend using a 42” hood, however a 36” hood is adequate.
M
K
O
L
J
G
H
N 1 N 2
I
Note: Support deck must be able to support a total weight of Grill model : 200 lbs
6 burner model: 220 lbs
Figure 2
Note: If cooktop must stand beside a refrigerator, it is
important for proper air circulation that there be at least 5” (13
cm) of space between the two appliances.
Table
2
Dim | 36" Metro Cooktop | |
|
| |
G | Maximum 25" (63cm) | |
|
| |
H | Maximum 7 3/4" (21cm) | |
|
| |
I | 36 1/4" (92cm) | |
|
| |
J | Minimum 6" (15cm) | |
left and right side | ||
| ||
|
| |
K | 13"(33cm) | |
|
| |
L | Specify Width of Hood | |
|
| |
M | 24" (61cm) | |
|
| |
N1 | 30" min to 36" max | |
for standard and high back guard | ||
| ||
|
| |
N2 | 30" min to 32" max | |
for low profile back guard | ||
| ||
|
| |
O | 18" (45cm) | |
|
|