Installation Diagram- 30” Metro Cooktop Model 3805
A
C
D1 | B |
D2
D3
Air intake slots on underside of control panel must not be obstructed or covered.
Figure 1
| Dim | 30" Metro Cooktop | |
|
|
| |
| A | 26 5/8" (68cm) | |
|
|
| |
| B | 8 1/4" (21cm) | |
|
|
| |
| C | 29 3/4" (76 cm) | |
|
|
| |
| D1 | Standard profile:12 3/4"(32 cm) | |
| (as shown in diagram) | ||
|
| ||
|
|
| |
| D2 | low profile: 10 1/8" (26 cm) | |
| D3 | high back w/ shelf: | |
Table 1 | 28 1/4" (72cm) | ||
| |||
|
|
Clearances
•Minimum distance between the cooktop and a side wall above the cooktop surface is 6” (see dim "J" in Table 2 on next page)
•Depth of cutout must not exceed 25”. (see dimension G) Air intake slots on underside of control panel must not be obstructed or covered.
Electrical requirements:
• Electrical hookup must be done by a licenced electrician
• 120 Volts 60Hz .375 kW 3 prong plug 5
Gas Requirements:
•Gas
•Pressure requirements: Natural gas: 6” W.C. (min); LP gas: 11” W.C. (min)
•Connection: 1/2” NPT
•An accessible manual shut off valve must be installed at the appliance.
•Note: This unit contains a
•Natural Gas/Propane Conversion kits are available - must be done by a licensed gas fitter
7