Sears Clothes Dryer owner manual =I.oo Iiddddii, Opening dryer top

Page 15

9.Set new vend price by adding or removing the appropriate block-out keys and/or dime inserts according to Table of Vend Prices.

TABLE OF VEND PRICE

VENO

COIN BLOTB

PRICm

IRa4nSTn

oIIIIIIII

lo¢u1111111 25¢11DIIIII 35¢DIDIIIII 5o¢IIDDIIII

8o¢ DIDDIIII

75¢IIDDDIII

85¢ DIDDDIII

=I.oo IIDDDDII

=1.1o ulDDDDII =1.25 IDDDDDII =1.35 DIDDDDDI =1.5o IDDDDDDI

1.so uDDDDDDI =1.75 IDDDDDDD

=I.a5 uDDDDDDD

=2.oo IDDDDDDD

NOTES:

*Black slots are closed off by block-out key. To remove block-out keys, pull straight up.

*Be sure block-out keys and/or dime inserts are seated properly and ratchet dog is in place with its spring connected. Be sure the proper coin sizing block is in place.

Part # 20-3007 for up to 7 quarters and 1 dime Part # 20-3006 for up to 8 quarters and 0 dimes

*Unless otherwise ordered, all coin chutes are supplied with Part 20-3006 in place.

10.Plug in dryer or reconnect power.

NOTE: Refer to the product information sheet provided with the coin box for additional information.

Opening dryer top

Electrical Shock Hazard

Disconnect power before servicing.

Replace all panels before operating,

Failure to do so can result in death or electrical shock.

1.Unplug dryer or disconnect power.

2.Open meter-case access door with top-lock key.

3.Loosen the two timer bracket mounting screws (do not remove) and lift timer and mounting bracket out of meter case.

4.Remove nut and tee spacer from the stud.

yjf Security

Top Lock

Tee Spacer

5.Unlock the security top lock located in the front right corner of the dryer top with the key provided.

6.Remove two screws under lint lid,

7.Press in the top locks located 2½ inches in from each side of the dryer with a putty knife.

8.Lift the top as you press the locks. The top is hinged at the rear. Hold the top open. If you let go, the top could fall back and damage the console.

15

Image 15
Contents COIN-OPERATED Commercial Electricdryer Table of ContentsDryer Safety Strainrelief whiteorcenter Tools needed for installationThree-Wire Electrical Connection to Receptacle InstructionsTerminalblockcover Hold-downscrew Three-Wire Electrical Connection Direct WireOn next Alternate Connection Four-Wire Electrical Connection to ReceptacleExternal terminalblockscrew Neutral wire Greenwire Ofpowersupply Cordorbare. copperwireProng wimgreen terminals Leave bare grounding wire at 5 inches Four-Wire Electrical ConnectionDirect Wire Disconnect powerArece,,erw re I III. gr0ced .,w re To determine maximum vent length Determining vent lengthMultiple dryer exhausting guide Cardboard Starting the dryer without using the coin mechanism Installing coin-slide mechanismCoin box adjustment Final installation connectionChanging Vend Price Replacing nylon timing cams on accumulator mechanismOpening dryer top =I.oo IiddddiiLubrication Instructions Operating the DryerTo close dryer top Drying TimeTroubleshooting Motor Drying temperature too high Operating thermostatLoose components Secure component BeltPage Sears