Sears Clothes Dryer owner manual Three-Wire Electrical Connection Direct Wire

Page 4

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The power supply cord must be plugged into an appropriate outlet that is

properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug on the power supply cord. If it will not fit the outlet, have a proper outlet installed.

SAVETHESEINSTRUCTIONS

1.Disconnect power.

2.Remove hold-down screw and terminal block cover.

Terminalblockcover Hold-downscrew

3.Attach a ¾-inch, U.L.-listed, strain relief to the hole below terminal block opening. Strain relief should have a tight fit with dryer cabinet and be in a horizontal posi- tion. Put the power supply cord through the strain re-

lief.

Externalground

Center silver-colored

connector

terminal block screw

Neutral

(white)

Neutral ground-

_", U.L.-listed,

ing wire

strain relief

(green/_/ellow)

 

4.Loosen or remove terminal block screws. Connect the

neutral wire (white or center) of power supply cord under the center screw of the terminal block.

5.Connect the other two wires to outer terminal block screws. Tighten all terminal block screws firmly.

6.Tighten the strain relief screws.

7.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw.

NOTE: If local codes do not permit the connection of a

frame-grounding conductor to the neutral wire, see the in- structions for "Alternate Connection" later in this section.

Three-Wire Electrical Connection (Direct Wire)

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections. Failure to follow these instructions can result in death, fire, or electrical shock.

GROUNDING INSTRUCTIONS

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment- grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

SAVE THESE INSTRUCTIONS

4

Image 4
Contents Table of Contents COIN-OPERATED Commercial ElectricdryerDryer Safety Tools needed for installation Three-Wire Electrical Connection to ReceptacleInstructions Strainrelief whiteorcenterThree-Wire Electrical Connection Direct Wire Terminalblockcover Hold-downscrewOn next Four-Wire Electrical Connection to Receptacle Alternate ConnectionGreenwire Ofpowersupply Cordorbare. copperwire External terminalblockscrew Neutral wireProng wimgreen terminals Four-Wire Electrical Connection Direct WireDisconnect power Leave bare grounding wire at 5 inchesArece,,erw re I III. gr0ced .,w re Determining vent length To determine maximum vent lengthMultiple dryer exhausting guide Cardboard Installing coin-slide mechanism Coin box adjustmentFinal installation connection Starting the dryer without using the coin mechanismReplacing nylon timing cams on accumulator mechanism Changing Vend Price=I.oo Iiddddii Opening dryer topOperating the Dryer To close dryer topDrying Time Lubrication InstructionsTroubleshooting Drying temperature too high Operating thermostat Loose components Secure componentBelt MotorPage Sears