Sears Clothes Dryer owner manual Arece,,erw re I III. gr0ced .,w re

Page 9

5.Connectneutralgroundingwireandtheneutralwire

(whiteorcenter)of directwirecableunderthecenter screwofterminalblock.

Center silver-colored terminal blockscrew

Externalground

Neutral wire (white)

connector

/

 

 

II

II

dL

The dryer must be properly installed and vented to

achieve maximum drying efficiency. Install the dryer in a well-ventilated room where the temperature is always above 45°R Also make sure that the dryer is

leveled. If the dryer is not properly installed and vented, it will not be covered under the warranty.

NOTE: Service calls caused by improper venting will be paid for by the customer, whether it was a paid installa- tion or self-installed. For paid installation, call the company that installed the vent for adjustment.

,arece,,erw re I III". gr0ced .,w re

_ (green/yellow)

¾", U.L-listed, strain relief

6.Place the hook-shaped end of the wire over the terminal block screw. The open side of the hook should face to the right. Squeeze hook end of wire together to form a loop.

7.Connect the other two wires to outer terminal block screws. Use the same method described in Step 6.

8.Connect the direct wire cable (bare) grounding wire to the external-grounding conductor screw. Tighten all terminal block screws firmly.

9.Tighten the strain relief screws.

10.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw.

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer

MUST BE EXHAUSTED OUTDOORS.

*Do not exhaust dryer into a chimney, a wall, a ceiling, or a concealed space of a building.

*The diameter of the heavy metal vent must be 4 inch.

*Do not use an exhausted hood with a magnetic latch.

If using an existing exhaust system, remove lint. Make sure exhaust hood is not plugged with lint.

*Disconnect vent from the dryer and clean one section at a time until you reach the exhaust hood.

*Use the hose attachment on your vacuum, or a pole with a feather duster or rag attached, to clean out lint.

*Be sure the flapper on the outside end of vent moves freely.

*When cleaning is complete, be sure to follow these Installation Instructions for final product check.

Clean exhaust vent periodically, depending on use, but at least every 2 years, or when installing your dryer in a new location.

continued on next page

9

Image 9
Contents COIN-OPERATED Commercial Electricdryer Table of ContentsDryer Safety Three-Wire Electrical Connection to Receptacle Tools needed for installationInstructions Strainrelief whiteorcenterTerminalblockcover Hold-downscrew Three-Wire Electrical Connection Direct WireOn next Alternate Connection Four-Wire Electrical Connection to ReceptacleExternal terminalblockscrew Neutral wire Greenwire Ofpowersupply Cordorbare. copperwireProng wimgreen terminals Direct Wire Four-Wire Electrical ConnectionDisconnect power Leave bare grounding wire at 5 inchesArece,,erw re I III. gr0ced .,w re To determine maximum vent length Determining vent lengthMultiple dryer exhausting guide Cardboard Coin box adjustment Installing coin-slide mechanismFinal installation connection Starting the dryer without using the coin mechanismChanging Vend Price Replacing nylon timing cams on accumulator mechanismOpening dryer top =I.oo IiddddiiTo close dryer top Operating the DryerDrying Time Lubrication InstructionsTroubleshooting Loose components Secure component Drying temperature too high Operating thermostatBelt MotorPage Sears