Sears Clothes Dryer owner manual Four-Wire Electrical Connection, Direct Wire, Disconnect power

Page 8

Four-Wire

Electrical

Connection

1. Disconnect power.

Direct Wire)

 

Strip 5 inches of outer covering from end of cable.

 

 

 

Leave bare grounding wire at 5 inches.

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections. Failure to follow these instructions can result in death, fire, or electrical shock.

Cut 1 inch from 3 remaining insulated wires. Strip insulation back 1 inch. Shape the end of each wire into a "U" shaped hook.

2.Remove hold-down screw and terminal block cover.

Terminalblockcover Hold-downscrew

GROUNDING INSTRUCTIONS

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment- grounding conductor must be run with the circuit conductors and connected to the equipment- grounding terminal or lead on the appliance.

SAVE THESE INSTRUCTIONS

The dryer can be connected directly to fused disconnect or circuit breaker box with four-wire, flexible armored or non-metallic sheathed copper cable (with grounding wire). All current-carrying wires must be insulated. The ground- ing wire may be bare.

A conduit connector must be installed at junction box. Allow four feet of slack in the line so dryer can be moved if servicing is ever necessary.

3.Attach a H-inch, U.L.-listed, strain relief to the hole below terminal block opening. Strain relief should have a tight fit with dryer cabinet and be in a

horizontal position. Put the direct wire cable through the strain relief.

4.Remove the center terminal block screw. Remove the neutral grounding wire (green/yellow wire) from external grounding screw.

External ground

Center silver-colored

 

terminal blockscrew

Green/yellow wire of harness

8

Image 8
Contents Table of Contents COIN-OPERATED Commercial ElectricdryerDryer Safety Tools needed for installation Three-Wire Electrical Connection to ReceptacleInstructions Strainrelief whiteorcenterThree-Wire Electrical Connection Direct Wire Terminalblockcover Hold-downscrewOn next Four-Wire Electrical Connection to Receptacle Alternate ConnectionProng wimgreen terminals External terminalblockscrew Neutral wireGreenwire Ofpowersupply Cordorbare. copperwire Four-Wire Electrical Connection Direct WireDisconnect power Leave bare grounding wire at 5 inchesArece,,erw re I III. gr0ced .,w re Determining vent length To determine maximum vent lengthMultiple dryer exhausting guide Cardboard Installing coin-slide mechanism Coin box adjustmentFinal installation connection Starting the dryer without using the coin mechanismReplacing nylon timing cams on accumulator mechanism Changing Vend Price=I.oo Iiddddii Opening dryer topOperating the Dryer To close dryer topDrying Time Lubrication InstructionsTroubleshooting Drying temperature too high Operating thermostat Loose components Secure componentBelt MotorPage Sears