TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

3-WIRE SYSTEM CONNECTIONS

1.Loosen or remove center terminal block screw.

2.Connect neutral wire (white or center wire) of the power cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Tighten strain relief screws.

5.Insert tab of terminal block cover into your dryer’s rear panel slot. Secure cover with hold-down screw.

1. External ground connector

2. Neutral grounding wire (green/yellow)

3. Center silver-colored terminal block screw

4. Neutral wire (white or center wire)

5.3/4” (1.9 cm) UL-listed strain relief

WARNING: If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected to the terminal block support to ground the dryer frame to the neutral conductor.

4-WIRE SYSTEM CONNECTIONS

1.Remove center terminal block screw.

2.Connect ground wire (green or unwrapped) of power cord to external ground conductor screw.

3.Connect neutral wire (white or center wire) of power cord and appliance ground wire (green with yellow stripes) under central screw of the terminal block.

4.Connect the other wires to outer terminal block screws. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into your dryer’s rear panel slot.

Secure cover with hold-down screw. 1. External ground connector

2. Green or bare copper wire of power cord

3. 3/4 in. (1.9 cm) UL-listed strain relief

4. Center silver-colored terminal block screw 5. Grounding wire (green/yellow)

6.Neutral wire (white or center wire)

11

Technical_information-02365B.ind11 11

2008-06-25 ¿ÀÈÄ 5:24:30

Image 11
Contents Clothes Dryer Alignment and Adjustments Special Test Mode Continuous Run ModeSystem Check Mode Sensor Bar Touch Data ModeCycle Count Mode Software Version ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Function 1M 2M 3M 5M 6M Component Testing ProceduresThermostat 60T21 Hi-Limit230F-50F Resistance value 1 Ω Radiant Sensor10RSIgniter101D Gas Valve25M01ACN1 RY5 RY6 AC Power Port Motor Relay SwitchWire System Connections Wiring Diagram