Samsung DV338 service manual Continuous Run Mode, Special Test Mode

Page 3

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

TEST MODE

Continuous Run Mode

Continuous Run Mode:

1.Press Signal + Dry Level for 3 sec during Power On State (Normal User Mode) .

2.Once in Continuous Run Mode, 7-Segment will toggle display “total cycle” and the remain- ing time.

3.The previous cycle will restart during Continuous Run Mode until continuous run mode is disabled.

4.During Continuous Run Mode, press Signal + Dryness Level for 3 seconds to return

to normal user mode. 7-segment will no long display “total cycle ” and only display the remaining time.

Special Test Mode

Definition of Special Test Mode:

-Dryer must be on before Service Mode can be entered.

-Press Signal and Temp Keys for 3 seconds, or until 3 beeps are heard.

-The machine will now be in Service Mode.

-Upon entry into Service Mode, the Sensor Bar Touch Data will be shown (Default Special Test Mode).

How to Enter:

-To enter Special Test Mode press Signal and Temp Keys for 3 seconds for 3 seconds or until the control beep.

Technical_information-02365B.ind3 3

2008-06-25 ¿ÀÈÄ 5:24:23

Image 3
Contents Clothes Dryer Alignment and Adjustments Special Test Mode Continuous Run ModeSystem Check Mode Sensor Bar Touch Data ModeCycle Count Mode Software Version ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Function 1M 2M 3M 5M 6M Component Testing ProceduresThermostat 60T21 Hi-Limit230F-50F Resistance value 1 Ω Radiant Sensor10RSIgniter101D Gas Valve25M01ACN1 RY5 RY6 AC Power Port Motor Relay SwitchWire System Connections Wiring Diagram