Samsung DV338 service manual Alignment and Adjustments

Page 2

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

ERROR ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5sec and con tinuously show one of the Error Displays from the following errors.

Error Display

Trigger

Action Taken

 

 

LED

LCD

 

 

 

 

 

 

tS

 

The Thermistor

Check for :

 

 

- Clogged lint screen

 

 

resistance is very low or

 

 

- Restricted vent system.

tO

 

high.

 

- Check Thermistor resistance.

 

 

 

 

 

 

 

 

 

Check for :

 

 

Running the dryer with

- Close the door, and run the

dO

 

dryer

 

door open

 

 

- Loose or open wire terminals

 

 

 

 

 

 

in Door sense circuit.

 

 

 

Check for :

dF

 

Invalid state for more

- Loose or open wire terminals

 

than 256 milliseconds

in Door

 

 

 

 

 

sense circuit.

 

 

Invalid state of key

Check for :

bE

 

- Display PCB key circuit short

 

circuit short for 75secs

 

 

or not

 

 

 

 

 

 

 

 

 

 

Check for :

od

 

Invalid Dry time in

- Sensor bar Open

 

excess Dry time

- Using Adjust time Up exces-

 

 

 

 

 

sively

 

 

Invalid heating Temp in

Check for :

hE

 

- Restricted vent system.

 

running the dryer

 

 

- Check Thermistor resistance.

 

 

 

 

 

 

 

Et

 

Invalid state of Eeprom

Check for :

 

communication

- PCB on Eeprom circuit

 

 

 

 

 

 

 

 

 

Check for :

 

 

Invalid power source

- Not using regular power

FE

 

source frequency

 

Frequency

 

 

- Invalid power frequency sense

 

 

 

 

 

 

circuit

Technical_information-02365B.ind2 2

2008-06-25 ¿ÀÈÄ 5:24:23

Image 2
Contents Clothes Dryer Alignment and Adjustments Continuous Run Mode Special Test ModeSoftware Version Mode Sensor Bar Touch Data ModeCycle Count Mode System Check ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Component Testing Procedures Function 1M 2M 3M 5M 6MGas Valve25M01A Radiant Sensor10RSIgniter101D Thermostat 60T21 Hi-Limit230F-50F Resistance value 1 ΩAC Power Port Motor Relay Switch CN1 RY5 RY6Wire System Connections Wiring Diagram