TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

COMPONENT TESTING PROCEDURES

Component Electrical Testing (with ohmmeter)

Belt Cut-off S/W

Thermistor resistance 10K Ω @ 25°C 77°F

- Lever open: Resistance value < 1Ω

(2P-Blue & Red wire)

- Lever push: Resistance value

Thermostat 1 resistance < 1Ω (White &

 

Yellow wire)

 

Thermostat 3 resistance < 1Ω (Red &

Black wire)

-If resistance is infinity, replace thermostat 3.

Thermostat 2 resistance < 1Ω (Blue &

Black wire)

-If resistance is infinity, replace thermostat 2.

Heater resistance 10 Ω (Blue & Blue wire) -If resistance is infinity, replace Heater.

Measure resistance of the following terminal

1)Door switch knob: open

Terminal : “COM” - “NC” (1-3) : ∞ Ω

Terminal : “COM” - “NO” (1-2) < 1Ω

2)Door switch push: On

Terminal : “COM” - “NC” (1-3) : ∞ Ω

Terminal : “COM” - “NO” (1-2) < 1Ω

Lamp resistance 80~100 Ω (Violet & gray)

Motor (Electronic & GAS) Contacts

Function 1M 2M 3M 5M 6M

Start

Run

= Contact closed

Centrifugal Switch (Motor)

2.88Ω between Pin# 3 and 4

3.5Ω between Pin# 4 and 5

Technical_information-02365B.ind8 8

2008-06-25 ¿ÀÈÄ 5:24:26

Image 8
Contents Clothes Dryer Alignment and Adjustments Continuous Run Mode Special Test ModeSensor Bar Touch Data Mode Cycle Count ModeSoftware Version Mode System Check ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Component Testing Procedures Function 1M 2M 3M 5M 6MRadiant Sensor10RS Igniter101DGas Valve25M01A Thermostat 60T21 Hi-Limit230F-50F Resistance value 1 ΩAC Power Port Motor Relay Switch CN1 RY5 RY6Wire System Connections Wiring Diagram