Samsung DV338 service manual Radiant Sensor10RS, Igniter101D, Gas Valve25M01A

Page 9

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

GAS MODEL

Radiant Sensor(10RS)

Resistance value < 1 Ω

If resistance is infinite, replace Radiant sensor

Igniter(101D)

Resistance value 40~400 Ω

If resistance is infinite, replace Igniter

Gas Valve(25M01A)

Valve 1-2 : Resistance value 1.2K Ω

Valve 1-3 : Resistance value 0.5K Ω

Valve 4-5 : Resistance value 1.2K Ω If resistance is infinity, replace Valve

Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω

If resistance is infinity, replace Thermostat

Technical_information-02365B.ind9 9

2008-06-25 ¿ÀÈÄ 5:24:27

Image 9
Contents Clothes Dryer Alignment and Adjustments Special Test Mode Continuous Run ModeCycle Count Mode Sensor Bar Touch Data ModeSoftware Version Mode System Check ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Function 1M 2M 3M 5M 6M Component Testing ProceduresIgniter101D Radiant Sensor10RSGas Valve25M01A Thermostat 60T21 Hi-Limit230F-50F Resistance value 1 ΩCN1 RY5 RY6 AC Power Port Motor Relay SwitchWire System Connections Wiring Diagram