Samsung DV338 service manual Sensor Bar Touch Data Mode, Cycle Count Mode, Software Version Mode

Page 4

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Sensor Bar Touch Data Mode

Definition of Sensor Bar Touch Data Mode:

-While in Power On pressing Signal and Temp Keys for 3 seconds

-This action will put the dryer into sensor bar touch data mode

-Dryer will display Sensor Bar data. This mode is default mode of entering service mode

How to Enter:

- While in Power off pressing Signal and Temp Keys for 3 seconds

Cycle Count Mode

Definition of Cycle Count Mode:

-While in Service Mode pressing the Signal key will put the dryer into the cycle count mode

-Cycle number executed will display.

How to Enter:

-To enter Special Test Mode press While in Service Mode pressing the Signal key for 3 seconds or until the control beep.

Software Version Mode

Definition of Software Version Mode:

-While in Service Mode pressing the Temp key will put the dryer into the software version mode

How to Enter:

-To enter Special Test Mode press Temp Key until the control beep.

ex) In case of “U105”, U0 means major version “v1“ 05 means minor version “05”

System Check Mode

Special Test Mode:

-While in Power Off, pressing the Dryness Level + Power keys simultaneously will put the dryer into the System Check mode

-“ t2 “ will display.

-System Check Mode Progress

t2 mode Function Performed Start/Pause Motor(CW) Relay On → Heater Relay On → Heater Relay Off → Motor(CW) Relay Off (Circulation)

Technical_information-02365B.ind4 4

2008-06-25 ¿ÀÈÄ 5:24:23

Image 4
Contents Clothes Dryer Alignment and Adjustments Continuous Run Mode Special Test ModeSensor Bar Touch Data Mode Cycle Count ModeSoftware Version Mode System Check ModeTrouble Shooting All wires are hooked up to their corresponding terminals Goes out, check for the following Component Testing Procedures Function 1M 2M 3M 5M 6MRadiant Sensor10RS Igniter101DGas Valve25M01A Thermostat 60T21 Hi-Limit230F-50F Resistance value 1 ΩAC Power Port Motor Relay Switch CN1 RY5 RY6Wire System Connections Wiring Diagram