36 inch standpipe recommended
If standpipe is less than 36 inches (or floor drain) – drain hose should be routed through the clip to raise hose to the proper height, use clip tie to securely hold drain hose in clip.
Installation accessory kits are available for other types of drain facility conditions…see Washer Installation Accessory Kits table on page 13.
The use of a laundry
If the faucets and/or drain is located to either side of the stacked washer/dryer, openings are located in the dryer stand uprights to allow hoses and power cords to be passed through. This is to allow installation against the back wall. (This is dependent on venting used.)
GAS CONNECTION
Gas operated dryers are equipped with a burner orifice for operation on NATURAL GAS. If the dryer is to be operated on LP GAS, it must be converted correctly for safety and proper performance. Conversion kits from NATURAL to LPG, or LPG to NATURAL are available through your local Maytag dealer. If other conversions are required, check with local gas utility for specific information concerning conversion requirement. NOTE: The conversion should always be performed by a qualified service technician.
NOTE: If the dryer is to be converted in Canada, the conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN- B149.1 and
A 1/2 inch gas supply line is recommended and must be reduced to connect to the 3/8 inch gas line on the dryer.
IMPORTANT NOTE: When installing the gas line, route it so that it will not interfere with the washer once the washer is pushed back into position. It is important to make sure the gas line does not come into contact with either the washer drain hose or any part of the washer.
NOTE: A 3/8 inch x 1 inch pipe nipple is includ- ed to adapt valve connection from a 3/8 inch female to a 3/8 inch male I.P.S. connection.
Additionally, a 1/8 inch N.P.T. (National Pipe Thread) plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer.
Gas Line
1/8" NPT Plug
Dryer
Gas Line
Refer to your local gas utility or plumbing contractor should you have questions on the installation of the plugged tapping.
The dryer and its individual
The dryer must be isolated from the gas supply piping system by closing its individual manual
The gas supply should be connected to the dryer using pipe joint compound or a Teflon tape on male thread connections. NOTE: Any pipe joint compound used must be resistant to the action of any liquefied petroleum gas.
Turn on gas supply and open the
NOTE: As a courtesy, many local gas utilities will inspect a gas appliance installation. Check with your utility to see if this service is provided in your area.
GAS IGNITION
This dryer uses an automatic ignition system to light the main burner when the dryer is turned on.
8 | printed in U.S.A. |