3. INSTALLATION

3.3Wiring

3.3.1Standalone configuration

For standalone configuration the junction box is not necessary; connect the instrument directly to the power supply.

+

 

Black

Red

 

NMEA 2000

 

NMEA 2000

drop cable

 

SENSOR

12 VDC

 

FI-50-DROP

 

 

 

 

Cable (6 m)

 

 

Display Unit

 

 

FI-504

 

.

3.3.2Multi-instrument configuration

FI-50-CHAIN

(0.3 m: Std, 1/5/10/20 m: Option)

DISP. UNIT

 

 

FI-501/502/FI-503/FI-505/FI-506

DISP. UNIT

(Instruments can be connected

FI-504

in any order.)

Instruments chained

 

 

as above

 

Instruments chained

 

as above

 

 

FI-5002

 

 

POWER CABLE (2 m)

 

Black – + Red

 

Instruments chained as above

Instruments chained as above

Instruments chained as above

FI-50-DROP Cable

(6 m, standard supply)

JUNCTION BOX FI-5002 (optional supply)

NMEA 2000 Backbone Cable (local supply)

FI-50X FI-50X FI-50X

JUNCTION BOX FI-5002

The total length of drop cables and backbone cables must be within 80 m.

18

Page 26
Image 26
Furuno FI-504 manual Wiring, Multi-instrument configuration