3. INSTALLATION

Turn on the terminal resistor in the junction box when the NMEA 2000 sensor(s) connected to it do not have a terminal resistor.

Terminal Resistor

OFF:

ON:

For how to turn on the terminal resistor in a FI-50 series instrument, see page 33 (FI-501//FI-502/FI-505) or page 35 (FI-506).

3.4Setting Up

Your instrument is pre-programmed with factory default settings, which may or may not be suited to your vessel. Therefore, it is necessary to ini- tialize the instrument for use with your vessel. This should be done im- mediately after completion of the installation.

Two sets of setup menus are provided: setup1 and setup2. The setup1 menu provides system parameters and the setup2 menu has user set- tings.

3.4.1Setup1 menu

The setup1 menu contains system parameters which optimize the instru- ment for use on your vessel. Follow the procedure below to access and set parameters.

1.Press the APP/TRUE and SELECT/CLEAR keys momentarily to enable the setup1 menu. The Depth unit selection screen appears, with the depth unit flashing. (See the illustration on the next page.)

2.Use the DISP key to select a menu item. Each press of the key changes the menu item in the sequence shown in the illustration on the next page.

21