1. OPERATION

Alarm description

Alarm

Alarms released when;

Setting range

 

 

 

Low battery voltage

battery voltage is lower than

5.0 - 20.0 volts

alarm

this threshold.

 

2.If the selected alarm page shows “Off,” press and hold down the SELECT/CLEAR key until an alarm setting appears.

3.Press the APP/TRUE and SELECT/CLEAR keys together to enable adjustment. The alarm setting starts flashing.

4.Press the APP/TRUE key to lower the setting; the SELECT/CLEAR key to raise it.

Note: A low alarm cannot be set higher than its affiliated high (max.) alarm.

5.Press the APP/TRUE and SELECT/CLEAR keys together to confirm setting and restore normal operation.

When an alarm is violated, the buzzer sounds and the alarm icon ( ) flashes. You can silence the buzzer with the SELECT/CLEAR key. The icon continues flashing until the offending alarm is disabled.

While the icon is flashing you can switch between alarm display and cur- rent display alternately by pressing the DISP and SELECT/CLEAR keys together.