Furuno FI-504 manual MAX38.9 LO9.7 12.2, Alarms

Models: FI-504

1 45
Download 45 pages 13.55 Kb
Page 17
Image 17

1. OPERATION

1.7Alarms

There nine conditions which trigger audio and visual alarms: Shallow alarm, Deep alarm, Shallow anchor alarm, Deep anchor alarm, Max. true wind speed alarm, Low true wind speed alarm, High apparent wind angle alarm, low apparent wind angle alarm, and low battery voltage alarm.

1.Use the DISP and MODE keys to select desired alarm page, referring to the illustration below for alarm location.

Display

 

 

Available alarms

 

 

category

 

 

 

 

 

 

 

 

 

 

DEPTH

SHALLOW

DEEP

 

SHALLOW

DEEP

 

 

 

020

150

 

5.0

10.0

 

Shallow alarm

Deep alarm

Shallow anchor

Deep anchor

 

 

 

 

alarm

alarm

WIND

TRUE

KT

TRUE KT

 

APP S* HI

APP S* LO

 

 

 

MAX38.9

LO9.7

 

12.2

5.4

 

Max. true wind

Low true wind

High apparent

Low apparent

 

speed alarm

speed alarm

wind angle alarm

wind angle alarm

ENVIRON-

VOLTS

 

 

 

 

 

MENT

 

 

 

 

 

LO

 

 

 

 

 

 

9.0

 

 

 

 

 

Low voltage

 

 

 

 

 

alarm

 

 

 

 

 

 

 

 

 

 

*S (Starboard) or P (Port)

.

 

 

 

 

 

 

 

 

 

Alarm description

 

 

Alarm

Alarms released when;

 

Setting range

Shallow alarm

 

depth is shallower than this

 

0.0-303 m

 

 

 

threshold.

 

 

 

Deep alarm

 

depth is deeper than this

 

0.1-304 mt

 

 

 

threshold.

 

 

 

Shallow anchor alarm

anchor depth is shallower than

depth is shallower than this

 

 

this threshold.

 

threshold.

 

Deep anchor alarm

anchor depth is greater than

depth is deeper than this

 

 

this threshold.

 

threshold.

 

Max. true wind speed

max. true wind speed is

 

0.1-999 kts

 

alarm

 

greater than this threshold.

 

 

 

Low true wind speed

true wind speed is lower than

0-998 kts

 

alarm

 

this threshold.

 

 

 

High apparent wind

apparent wind angle is higher

0°-179°

 

angle alarm

 

than this threshold.

 

S180°-P1°

 

Low apparent wind

apparent wind angle is lower

(S=Starboard, P=Port)

angle alarm

 

than this threshold.

 

 

 