Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
READING ERROR CODES
1.
Digital Readout Display Models: Rotate cycle selector knob clockwise (3) settings from the Normal cycle option.
2.Press and hold the Select and Pause Cancel buttons simultaneously for six seconds.
3.Immediately after, press and hold the START and Pause Cancel buttons simultaneously for 4 seconds.
4.Digital Readout Display Models: rotate the timer knob (1) click counterclockwise. The error code will appear in the digital display.
NOTE: A letter appearing in the code stands for a number higher than nine. A = 10 B = 11 C = 12 D = 13 E = 14 F = 15
Example Code E4A: the first digit would be 4 and the second digit would be 10. If this code would appear on a washer in the
To move on to the next code, press the OPTIONS button.
To clear code, press the Select button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the Select and Pause Cancel buttons for six seconds.
Error Code | Label | Description | Solution |
E10 | General EEPROM | Problem with communication | Clear code, exit mode and start dryer. If problem persists, replace electronic |
| Fault | between EEPROM and the | control. |
|
| microprocessor. |
|
E11 | Checksum Error | Problem with communications or | Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
| memory did not check, one has | control. |
|
| become corrupted. |
|
E12 | Non fatal R/W | Problem reading or writing to the | Clear code, exit mode and start dryer. If problem persists, replace electronic |
| error | memory or input/output. | control. |
E24 | Control NTC Short | Control thermistor or its wiring is | Remove wires from control thermistor. Measure resistance of thermistor. If |
| Circuit | shorted. | reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± |
|
|
| 10%), check wiring between thermistor and electronic control. If good, |
|
|
| replace electronic control. |
E25 | Control NTC Open | Control thermistor or its wiring is | Remove wires from control thermistor. Measure resistance of thermistor. If |
| Circuit | open. | reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± |
|
|
| 10%), check wiring between thermistor and electronic control. If good, |
|
|
| replace electronic control. |
E4A | Program Timeout | The drying time has exceeded | Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. |
| Fault | program time for that cycle. | Position cycle selector to NORMAL, temperature selector to HIGH HEAT |
|
|
| and touch START. Check for anything that would extend dry times such as: |
|
|
| no heat, restricted vent, blower fan blade broken or loose, dryer installed in |
|
|
| closet with solid door, or bad connection in moisture sensor bar circuit or |
|
|
| dirty bars. If dryer operates normally but code returns, replace electronic |
|
|
| control. |
E5B | Heater Fault (no | Temperature reading of control | Position cycle selector to NORMAL, temperature selector to HIGH HEAT |
| heating) | thermistor has not changed in a | and touch START. Measure voltage across terminals on relay K2 (heater |
|
| certain amount of time. | relay) on electronic control. If meter reads 240V on electric models and |
|
|
| 120V on gas models, replace electronic control. If meter reads zero, remove |
|
|
| power from dryer. Disconnect wire going to NO terminal on the relay K2. |
|
|
| Reconnect power and measure voltage drop between terminal COM on |
|
|
| relay K2 and neutral. If meter reads zero, wire between incoming line and |
|
|
| relay K2 is open. If meter reads 120V, check the rest of the heater circuit. |
E68 | Key (button) Struck | One of the keys (buttons) is stuck | Enter function test mode and perform key (button) test to determine which |
| Fault | closed (active). | button is at fault. Carefully free the and perform the test again. If button is |
|
|
| free but the key struck code still exists, replace electronic control. |
|
|
|
|
E8C | Too many trips in a | The safety (high limit) thermostat | Check for blocked lint filter, blocked exhaust, air leaks around air duct, |
| period of time. | has tripped too many times within | broken blower fan blades, worn or loose drum seals, dryer installed in closet |
|
| a certain period of program time. | with solid doors or door seal not correctly seated. |
|
|
|
|
EAF | Watch Dog Reset | Microcontroller has been reset by | Clear code, exit mode and start dryer. If problem persists, replace electronic |
|
| internal Watchdog timer. | control. |
|
|
|
|