ObjectiveImplementation
Adjusting the level of conductivity
Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to geographical locations thus varying its conductivity values.
Relevant variations of the conductivity of the water compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of the cycle. Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity values of the water by using the following procedure.
To access adjustment mode:
1.Turn the programme selector dial to switch on the appliance.
2.In selection mode,press simultaneously the buttons and .
Press the buttons down until until «C0» appears on the digits. Adjusting the level of conductivity:
Press the Delay Start button sequentially: the level of conductivity is indicated by the lighting of the horizontal hyphens.
Display |
| Conductivity | Approximate value µS/cm |
CO |
| Low | < 300 |
CO |
| Medium |
|
CO |
| High | >600 |
|
Normally, the appliance is
Memorizing the new setting:
Simultaneously press the buttons and . Press the buttons down until the previous drying cycle time appears again on the display and the buzzer sounds.
To reset a programme and to switch off the machine turn O = Cancelling/OFF the selector dial to O. Now can a new programme be