Connect the terminal labeled N and the Ground terminal labeled G with the supplied short cable. Tighten the terminals so that they securely hold the conductors.
9.Attach the two remaining power cord outer conductors to the 2 terminals labeled L. Tighten both screws so that the power conductors are securely held in place.
10.Tighten the strain relief so that the power cord cannot be moved.
11.Replace the cover on the junction box and fasten in place.
The dryer is now ready to be plugged into the
The receptacle should be located so that the plug and receptacle will be accessible with the dryer in its installed position.
Grounding Instructions
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an
•Power cord plug must be within easy reach after installation.
•The voltage and the allowed fuse/breaker protection are specified in the section
“Technical Specifications”.
•The stated voltage must match your mains voltage.
•Connection via extension cords or multi- plugs should not be made.
•The main fuse/breaker and switches must have a contact distance of minimum 3 mm.
BA damaged power cable must be replaced by a qualified electrician.
AWARNING – Improper connection of the
BThe appliance must not be operated unless it is repaired! There is the risk of electric shock!
Appropriate installation location
•Install your appliance in environments that have no risk of freezing and in a stable and level position.
•Do not place your appliance on a long pile rug or on similar surfaces.
•Operate your appliance in a
•Do not block the air ducts in front of and under the machine.
B Make sure that your appliance is not placed on the power cable.
A Keep at least 0.6” (1.5 cm) from the edges of other furniture.
9 - EN