Alliance Laundry Systems 70420801 installation manual Electrical Requirements

Page 10

Electrical Requirements

For 200 Pound Tumble Dryer Models

Serial Plate Rating

Terminal Block

Rated

Breaker

Recommended Wire

Connections Required

Current*

Rating

Size

 

 

 

 

 

 

200-208V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

240V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

400-415V/50Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

440V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

460-480V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

*Current ratings vary slightly depending on model; refer to serial plate.

Table 5

Page 10 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Image 10
Contents Model Identification SubjectPart No September Steam Models Net Weight approximate Pounds kg Cylinder Capacity dry weight Pounds kgGas Models Net Weight approximate Pounds kg Steam Coil Rating at 100 psigBoiler Horsepower Btu/hrCabinet Dimensions Models 200L/N/S Pound Tumble Dryer Dimensions and Exhaust Outlet LocationsExhaust Outlet Dimensions and Locations Models 200L/N/S Models Electrical Connection Gas Connection Electric and Gas Connection Locations for Gas Models200L/N Models Steam Inlet Diameter 200S Electric and Steam Connection Locations for Steam ModelsModels Electrical Connection 200S Position and Level the Tumble Dryer Make-Up AirExhaust Requirements ONE Manifold AssemblyDuct Pound Stations Mm Duct TWO Manifold Assemblies Non-CE Models Altitude Orifice New Gas RequirementsHigh Altitude Orifice Sizing Gas Rate Feet Inches QuantityElectrical Requirements Pounds Condensate/Hour Steam RequirementsSteam Pressure Supply ReturnLoading Door Strike Belt Drive