Alliance Laundry Systems 70420801 Cylinder Capacity dry weight Pounds kg, Gas Connection

Page 2

Specifications and Dimensions

Specifications

200 Pound

 

 

Noise level measured during operation at operator position of 3.3 feet

66 dBA

(1 meter) in front of machine and 5.2 feet (1.6 meters) from floor.

 

 

 

Cylinder Size: Inches (mm)

50.75 x 50

(1289 x 1270)

 

 

 

Cylinder Capacity dry weight: Pounds (kg)

200

(90.7)

 

 

 

Cylinder Motor Horsepower

0.75

 

 

Fan Motor Horsepower

3

 

 

Air Outlet Diameter: Inches (mm)

12

(300)

 

 

 

Maximum Static Back Pressure: W.C.I. (mbar)

0.3

(0.8)

 

 

 

Maximum Airflow: C.F.M (L/sec.)

2450

(1156)

 

 

 

Gas Models

 

 

 

Net Weight (approximate): Pounds (kg)

1707

(774)

 

 

 

Gas Connection

1 in. NPT

 

 

Gas Burner Rating: Btu/hr. (Mj/hr.)

425,000

(448)

 

 

 

Steam Models

 

 

 

Net Weight (approximate): Pounds (kg)

1807

(820)

 

 

 

Steam Connection

3/4 in. NPT inlet

1 in. NPT outlet

 

 

 

Steam Coil Rating at 100 psig:Boiler Horsepower (Btu/hr.)

18.8

(recommended operating pressure 80-100 psig)

(648,000)

 

 

Electric Models

 

 

 

Heating Element Rating:Kilowatts (kW)

N/A

 

 

N/A = Not Applicable

Page 2 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Image 2
Contents Part No September SubjectModel Identification Steam Models Net Weight approximate Pounds kg Cylinder Capacity dry weight Pounds kgGas Models Net Weight approximate Pounds kg Steam Coil Rating at 100 psigBoiler Horsepower Btu/hrExhaust Outlet Dimensions and Locations Models 200L/N/S Pound Tumble Dryer Dimensions and Exhaust Outlet LocationsCabinet Dimensions Models 200L/N/S 200L/N Electric and Gas Connection Locations for Gas ModelsModels Electrical Connection Gas Connection Models Electrical Connection 200S Electric and Steam Connection Locations for Steam ModelsModels Steam Inlet Diameter 200S Position and Level the Tumble Dryer Make-Up AirDuct Pound Stations Mm Duct ONE Manifold AssemblyExhaust Requirements TWO Manifold Assemblies Non-CE Models Altitude Orifice New Gas RequirementsHigh Altitude Orifice Sizing Gas Rate Feet Inches QuantityElectrical Requirements Pounds Condensate/Hour Steam RequirementsSteam Pressure Supply ReturnLoading Door Strike Belt Drive