Alliance Laundry Systems 70420801 Gas Requirements, High Altitude Orifice Sizing

Page 9

Gas Requirements

For converting Non-CE Models from Natural Gas to L.P. Gas:

200 Pound Models - M4975P3

High Altitude Orifice Sizing

For proper operation at altitudes above 2000 feet (610 meters), the gas orifice size must be reduced to ensure complete combustion. Refer to Table 4.

For CE models, consult local gas supplier.

Non-CE Models

 

 

Altitude

 

 

Orifice

 

 

New

Model

Gas

 

 

 

 

Rate

 

 

 

 

 

 

 

 

 

 

feet

m

No.

inches

mm

Quantity

Part No.

(Btu/hr.)*

 

 

2001 – 4000

610 – 1220

19

.1660

4.2

 

 

M402995

391,000

 

 

 

 

 

 

 

 

 

 

 

 

Natural

4001 – 6000

1221 – 1830

20

.1610

4.1

 

5

M401002

357,000

 

Gas

6001 – 8000

1831 – 2440

22

.1570

4.0

 

M402996

323,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200L/N

 

8001 – 10,000

2441 – 3050

24

.1520

3.9

 

 

M402980

289,000

 

 

 

 

 

 

 

 

 

 

 

2001 – 4000

610 – 1220

33

.1130

2.9

 

 

M401022

391,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L.P.

4001 – 6000

1221 – 1830

34

.1110

2.8

 

4

M411512

357,000

 

Gas

6001 – 8000

1831 – 2440

7/64

.1094

2.8

 

70070902

323,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8001 – 10,000

2441 – 3050

37

.1040

2.6

 

 

M401024

289,000

 

 

 

 

 

 

 

 

 

 

 

* Btu/hr. derate of 4% per 1000 ft. (305 m) of altitude.

Table 4

Page 9 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Image 9
Contents Subject Model IdentificationPart No September Gas Models Net Weight approximate Pounds kg Cylinder Capacity dry weight Pounds kgSteam Models Net Weight approximate Pounds kg Steam Coil Rating at 100 psigBoiler Horsepower Btu/hrPound Tumble Dryer Dimensions and Exhaust Outlet Locations Cabinet Dimensions Models 200L/N/SExhaust Outlet Dimensions and Locations Models 200L/N/S Electric and Gas Connection Locations for Gas Models Models Electrical Connection Gas Connection200L/N Electric and Steam Connection Locations for Steam Models Models Steam Inlet Diameter 200SModels Electrical Connection 200S Make-Up Air Position and Level the Tumble DryerONE Manifold Assembly Exhaust RequirementsDuct Pound Stations Mm Duct TWO Manifold Assemblies High Altitude Orifice Sizing Gas RequirementsNon-CE Models Altitude Orifice New Gas Rate Feet Inches QuantityElectrical Requirements Steam Pressure Steam RequirementsPounds Condensate/Hour Supply ReturnBelt Drive Loading Door Strike