AEG 56609 operating instructions Empty the condensate container

Page 19

Drying

Empty the condensate container

1 Caution! The condensate is not suitable for drinking or for use with foodstuffs.

Make it a habit to empty the condensate container after every drying process. This avoids automatic interruption of the drying process when the condensate container is full.

0Grasp the handle flap of the condensate

container and pull-out the latter completely.

0Push the cover of the condensate

container to the side and pour-out the condensed water.

0 Re-insert the condensate container into the operator control mask.

Information on illumination of the Z EMPTY WATER display:

The Z EMPTY WATER display remains illu- minated for a few seconds more after the condensation container is emptied.

If the drying cycle has not yet ended:

0Press the X START button to continue the drying cycle.

3 The condensate container has a capacity of approx. 3.8 litres. This is sufficient for a laundry fill of 5kg which has been centrifuged at 800 revolutions per minute.

19

Image 19
Contents Lavatherm 56609 Exclusiv Please read these operating instructions through carefully Dear customerContent Content General safety 1Safety instructionsUtilisation in accordance with the intended purpose Safety of childrenInstallation and connection General information Dispose of the packaging material DisposalPre-drying Drying process Environmental protection tipsFill weight Duration Power Drying program Front view Construction of the applianceOperator control mask Program selector Before the first drying processBrief operating instructions Fill-in the laundry DryingPreparing the laundry Open the fill-in doorStart the drying program Take out the laundry Take-out laundry or put-in laundry when necessarySwitch-off the dryer End of the drying processEmpty the condensate container Clean the condenser Clean the fluff filterProgram tables Care symbols R, Q fill-in quantity up to 5kgCool AIR Program Small glossary of textile information Care symbolsCleaning the condenser Cleaning and maintenanceClean the drum Cleaning the filter areaCleaning the panel and operating parts Problem Possible cause Remedy TroubleshootingOFF Replace the filament bulb Changing-over the door stop Changing-over the door stop Power supply Technical dataInformation for the electrician Kit for external condensate drain-off Special accessoriesKits Washing/drying column Use condensate Viscose Page When do you incur costs even during the warranty period? Service