American Dryer Corp MDG30V installation manual Specifications

Page 10

SECTION II

SPECIFICATIONS

A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

30 lbs

 

13.6 kg

BASKET (TUMBLER) DIAMETER

32-3/4”

 

83.2 cm

BASKET (TUMBLER) DEPTH

25-5/8”

 

65.1 cm

BASKET (TUMBLER) MOTOR

1/2 HP*

 

0.373 kw

DOOR OPENING (DIAMETER)

21-1/2”

 

54.61 cm

BASKET (TUMBLER) VOLUME

12.5 cu. ft.

 

0.354 cu.m.

DRYERS PER 20’/40’ CONTAINER

12/26

DRYERS PER 45’/48’ TRUCK

30/32

 

VOLTAGE AVAILABLE

120-460v 1ø - 3ø

3, 4w 50/60 Hz

Gas

APPROX. WEIGHT (UNCRATED)

534 lbs

 

242 kg

APPROX. WEIGHT (CRATED)

571 lbs

 

259 kg

HEAT INPUT

100,000 btuh

 

25,200 kcal/hr

 

AIRFLOW

460 cfm

 

13 cmm

 

INLET PIPE CONNECTION

1/2” F.P.T.**

Shaded areas are stated in metric equivalents

*MDG30V reversing dryer available with 3-phase (3ø) 1/2 HP (0.373 kw) motors standard.

**Size of piping to dryer varies with installation conditions. Contact factory for assistance.

NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents MDG30V Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions Explosion could ResultPage Specifications SpecificationsMDG30V Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Information Electrical RequirementsSingle-Phase 1ø Wiring Connections/Hookup Must be ProvidedSINGLE-PHASE 1Ø Electrical Connection Leads Important a Circuit Servicing Each Dryer Must be Provided Service Wire Approx Circuit Phase AMP Draw Voltage Breaker MDG30V GASGAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Coin ModelsPage OPL Models Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Adjustments LubricationLint Drawer Removal Troubleshooting StandardsBlower motor is not operating does not start Microprocessor controller computer display reads dSFL GAS Models only Dryer operates but is taking too long to dry Excessive noise and/or vibration Data Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components Page 113365 1 04/22/02-25