I. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
1.Turn on electric power to the dryer.
2.Refer to the Operating Instructions for starting your particular model dryer.
3.GAS MODELS ONLY
a.When a gas dryer is first started (during initial
NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.
NOTE: Gas model dryers are equipped with an ignition system, which has internal diagnostics. If ignition is not established after one (1) time, the heat circuit in the ignition module will attempt two (2) more ignitions (total of three [3] ignition attempts). If there is no flame after the third ignition attempt the module will lockout until it is manually reset. To reset the ignition system, open and close the main door and restart the dryer.
b.A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the pressure tap of the gas valve body):
Natural Gas
Liquid Propane (L.P.) Gas
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.
4.Make a complete operational check of ALL safety related circuits:
a.Door Switch(es)
b.
c.Cycling Thermostat
d.Sail Switch
NOTE: The sail switch can be checked for proper operation by opening the lint drawer. While pushing the lint drawer switch in, start a drying cycle. The heating unit should not activate (wait
28