American Dryer Corp M31SL manual Electrical Information, Electrical Requirements

Page 15

Important

!No more than 4 dryers should be connected to 1 main common duct.

The illustration below shows the minimum cross-sectional area for multiple dryer round or square venting. These figures must be increased if the main duct run from the last dryer to where it exhausts to the outdoors is longer than 12 feet (3.656 meters) or has more than 1 elbow in it.

A = M31SL 6-inch (15.24 cm)

M50SL 8-inch (20.32 cm)

M75SL 8-inch (20.32 cm)

B = 12 feet (3.656 meters)

NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening.

NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction.

Multiple Dryer Venting with 6-Inch (15.24 cm) Diameter

360 cfm (10.19 cmm) Exhaust Connections at Common Duct

M31SL

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SQ IN

80

80

54

30

 

 

 

 

SECTIONAL AREA

SQ CM

516.1

516.1

348.4

193.55

 

 

MINIMUM ROUND

IN

10

10

8

6

 

 

DUCT DIAMETER

CM

25.4

25.4

20.32

15.24

 

 

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

 

 

525 cfm (14.87 cmm) Exhaust Connections at Common Duct

 

 

 

 

 

 

 

 

 

M50SL

NUMBER OF DRYERS

4

3

2

1

 

MINIMUM CROSS-

SQ IN

120

120

80

54

 

 

 

 

SECTIONAL AREA

SQ CM

774.2

774.2

516.1

348.4

 

 

MINIMUM ROUND

IN

12

12

10

8

 

 

DUCT DIAMETER

CM

30.48

30.48

25.4

20.32

 

 

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

 

 

560 cfm (15.86 cmm) Exhaust Connections at Common Duct

 

 

 

 

 

 

 

 

 

M75SL

NUMBER OF DRYERS

4

3

2

1

 

MINIMUM ROUND

IN

12

12

10

8

 

 

MINIMUM CROSS-

SQ IN

120

120

80

54

 

 

SECTIONAL AREA

SQ CM

774.2

774.2

516.1

348.4

 

 

DUCT DIAMETER

 

 

 

 

 

 

 

CM

30.48

30.48

25.4

20.32

Electrical Information _________________

Electrical Requirements

All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and national regulations or codes of the country of origin. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

Important

!Failure to comply with these codes or ordinances, and/or the requirements stipulated in this manual

can result in personal injury or component failure.

Note

!Component failure due to improper installation will void the warranty.

Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could cause a fire hazard. The copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making all service connections.

Note

!The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each dryer, do not daisy chain.

Component failure due to improper voltage application will void the warranty.

The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

Important

!A separate protected circuit must be provided to each dryer.

The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

The wire size must be properly sized to handle the related current.

Warning

!208 VAC and 240 VAC are not the same. Any damage done to dryer components due to

improper voltage connections will automatically void the warranty.

113431 - 10

www.amdry.com

15

Image 15
Contents American Dryer Corporation M31SL / M50SL / M75SL Installation/Operator ManualRetain This Manual in a Safe Place for Future Reference Table of Contents What To Do If You Smell Gas Safety PrecautionsCE only 37.78 cm M31SL SpecificationsM31SL Specifications 40.64 cm M50SL SpecificationsM50SL Specifications M75SL Specifications M75SL Specifications Dryer Enclosure Requirements Installation ProceduresUnpacking/Setting Up Location RequirementsFresh Air Supply Requirements Exhaust RequirementsDomestic Type I M31SL, M50SL Only Vertical Venting Outside Ductwork ProtectionSingle Dryer Venting Horizontal VentingElectrical Requirements Electrical InformationElectric Models Only Electrical Service Specifications Gas and Steam Models OnlyFor CE Models Only Single-Phase 1ø Wiring Connections/HookupGrounding Electrical ConnectionsCE and Australian Dryers Gas InformationM31SL Piping/Connections Gas Specifications for AGA Approved Dryers AustraliaConverting from One Family Gas to Another Gas Pressure Adjustment Regulated Gas ValveConversion from Propane or Butane Gas to Natural Gas Steam Coil pH Level Gas Pressure TestingGas Pressure Test Procedure Steam InformationWater Information Preoperational Test Preparation for Operation/Start-UpShutdown Instructions Preoperational InstructionsCoin Models Non-Coin ModelsWarranty Information Service/Parts InformationRoutine Maintenance Standard Label AGA Label CE Label Data Label InformationADC Part No 10 06/04/08