American Dryer Corp M31SL Installation Procedures, Location Requirements, Unpacking/Setting Up

Page 12

Installation Procedures _______________

Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1-LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70- LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).

Location Requirements _______________

Before installing the dryer, be sure the location conforms to local, state, and country codes. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).

The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Dryers installed in residential garages must be elevated 18-inches (45.72 cm) above the floor.

Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements section).

Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements section).

Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements section).

The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual (refer to Exhaust Requirements section).

The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements section).

Important

!The dryer should be located where a minimum amount of exhaust ducting will be necessary.

The dryer must be installed with adequate clearance for air openings into the combustion chamber.

Caution

!This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months,

inspect the exhaust ducting and remove any lint buildup.

Important

!The dryer must be installed in a location/ environment, which the ambient temperature

remains between 40° F (4.44° C) and 130° F (54.44° C).

Unpacking/Setting Up _________________

Remove protective shipping material (i.e., plastic wrap and optional shipping box) from the dryer.

Important

!Dryer must be transported and handled in an upright position at all times.

The dryer can be moved to its final location while still attached to the skid or with the skid removed. To remove the skid from the M31SL, M50SL, or M75SL, locate and remove the 2 bolts securing the base of the dryer to the wooden skid. One is located at the center rear and the other is at the center front.

With the skid removed, use caution and assure all four leveling legs are fully retracted, if the dryer is to be slid into its final position.

Leveling Dryer

The dryer is equipped with 4 leveling legs, 1 at each corner of the base. For optimum performance the dryer should be level front-to-back and side-to-side.

Dryer Enclosure Requirements _______

Commercial Type II (M31SL, M50SL, M75SL)

Bulkheads and partitions should be made of noncombustible material.

Note

!Allowances must be made for opening the control door.

AThe requirement to allow the door to open completely for the M31SL is 33-inches (83.8 cm), and the M50SL and M75SL are 40-inches (101.6 cm).

BA minimum overhead clearance of 6-inches (15.24 cm) is required.

CDryer should be positioned a minimum of 12-inches (30.48 cm) away from the nearest obstruction. 24-inches (60.96 cm) is recommended for ease of installation, maintenance, and service.

D1/16” (1.5875 mm) minimum is required.

EFlooring should be level or below dryer cabinet for ease of removing panels during maintenance.

FDryers may be positioned sidewall to sidewall, however a 1/16” (1.5875 mm) minimum allowance must be made for the opening and closing of the control door, along with the removal of panels during maintenance.

12

American Dryer Corp.

113431 - 10

Image 12
Contents M31SL / M50SL / M75SL Installation/Operator Manual American Dryer CorporationRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only M31SL Specifications 37.78 cmM31SL Specifications M50SL Specifications 40.64 cmM50SL Specifications M75SL Specifications M75SL Specifications Installation Procedures Unpacking/Setting UpLocation Requirements Dryer Enclosure RequirementsFresh Air Supply Requirements Exhaust RequirementsDomestic Type I M31SL, M50SL Only Outside Ductwork Protection Single Dryer VentingHorizontal Venting Vertical VentingElectrical Information Electrical RequirementsElectrical Service Specifications Gas and Steam Models Only Electric Models OnlySingle-Phase 1ø Wiring Connections/Hookup GroundingElectrical Connections For CE Models OnlyGas Information CE and Australian DryersM31SL Gas Specifications for AGA Approved Dryers Australia Piping/ConnectionsConverting from One Family Gas to Another Gas Pressure Adjustment Regulated Gas ValveConversion from Propane or Butane Gas to Natural Gas Gas Pressure Testing Gas Pressure Test ProcedureSteam Information Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestPreoperational Instructions Coin ModelsNon-Coin Models Shutdown InstructionsService/Parts Information Warranty InformationRoutine Maintenance Data Label Information Standard Label AGA Label CE LabelADC Part No 10 06/04/08