American Dryer Corp M31SL manual M50SL Specifications, 40.64 cm

Page 8

M50SL Specifications _______________________________________________________________

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

50 lb

 

22.68 kg

 

TUMBLER DIAMETER

 

37”

 

93.98 cm

 

TUMBLER DEPTH

 

 

 

25-3/4”

 

65.41 cm

 

TUMBLER VOLUME

 

 

 

16.02 cu ft

453.64 L

 

TUMBLER/DRIVE MOTOR

 

3/4 hp

 

0.56 kW

 

BLOWER/FAN MOTOR

 

1/2 hp

 

0.37 kW

 

DOOR OPENING (DIAMETER)

 

27-3/8”

 

69.53 cm

 

DOOR SILL HEIGHT

 

 

 

16”

 

40.64 cm

 

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

 

DRYERS PER 20’/40’ CONTAINER

 

 

10 / 22

 

 

DRYERS PER 48’/53’ TRUCK

 

 

28 / 30

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

545 lb

 

247.21 kg

 

 

APPROXIMATE SHIPPING WEIGHT

565 lb

 

256.28 kg

 

Gas

AIRFLOW

 

 

60 Hz

525 cfm

 

14.87 cmm

 

 

 

 

 

50 Hz

437 cfm

 

12.37 cmm

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

90,000 Btu/hr

22,680 kcal/hr

 

 

EXHAUST CONNECTION (DIAMETER)

8”

 

20.32 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

INLET PIPE CONNECTION

 

 

1/2” M.N.P.T.

 

 

 

 

 

 

 

 

1/2” F.B.S.P.T. (CE and Australia Only)

 

 

VOLTAGE AVAILABLE

 

120-600V

1,3ø

2,3,4w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

545 lb

 

247.21 kg

 

Electric

APPROXIMATE SHIPPING WEIGHT

565 lb

 

256.28 kg

 

AIRFLOW

 

 

60 Hz

525 cfm

 

14.87 cmm

 

13.4

 

45,869

 

11,559

 

 

 

 

 

 

 

 

 

 

50 Hz

437 cfm

 

12.37 cmm

 

 

EXHAUST CONNECTION (DIAMETER)

8”

 

20.32 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.7

 

50,136

 

12,634

 

 

 

 

 

 

14.8

 

50,545

 

12,737

 

 

 

 

 

 

16.0

 

54,606

 

13,761

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

545 lb

 

247.21 kg

 

Steam

APPROXIMATE SHIPPING WEIGHT

565 lb

 

256.28 kg

 

AIRFLOW

 

 

60 Hz

525 cfm

 

14.87 cmm

 

 

 

 

 

50 Hz

437 cfm

 

12.37 cmm

 

 

 

 

 

 

 

 

 

STEAM CONSUMPTION

 

127.5 lb/hr

57.83 kg/hr

 

 

OPERATING STEAM PRESSURE

150 psi max

10.34 bar

 

 

EXHAUST CONNECTION (DIAMETER)

8”

 

20.32 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

3.75 Bhp

 

 

 

SUPPLY CONNECTION

 

 

3/4” F.N.P.T.

 

 

 

RETURN CONNECTION

 

 

3/4” M.N.P.T.

 

 

Shaded areas are stated in metric equivalents

 

 

 

 

4/30/07

!

Note

The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

8

American Dryer Corp.

113431 - 10

Image 8
Contents M31SL / M50SL / M75SL Installation/Operator Manual American Dryer CorporationRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only M31SL Specifications 37.78 cmM31SL Specifications M50SL Specifications 40.64 cmM50SL Specifications M75SL Specifications M75SL Specifications Installation Procedures Unpacking/Setting UpLocation Requirements Dryer Enclosure RequirementsDomestic Type I M31SL, M50SL Only Fresh Air Supply RequirementsExhaust Requirements Outside Ductwork Protection Single Dryer VentingHorizontal Venting Vertical VentingElectrical Information Electrical RequirementsElectrical Service Specifications Gas and Steam Models Only Electric Models OnlySingle-Phase 1ø Wiring Connections/Hookup GroundingElectrical Connections For CE Models OnlyGas Information CE and Australian DryersM31SL Gas Specifications for AGA Approved Dryers Australia Piping/ConnectionsConverting from One Family Gas to Another Conversion from Propane or Butane Gas to Natural Gas Gas Pressure AdjustmentRegulated Gas Valve Gas Pressure Testing Gas Pressure Test ProcedureSteam Information Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestPreoperational Instructions Coin ModelsNon-Coin Models Shutdown InstructionsService/Parts Information Warranty InformationRoutine Maintenance Data Label Information Standard Label AGA Label CE LabelADC Part No 10 06/04/08