American Dryer Corp M31SL manual

Page 19

Heat Input/Gas Consumption/Orifice (Injector) Data

(For Non-CE [European] and Non-AGA [Australia] Models Only)

Gas Specifications for Non-CE and Non-AGA Approved Dryers**

Model

Gas

Nominal

Supply

Gross

Orifice Size

Orifice

Burner

Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

Type

 

 

 

 

 

 

Quantity

 

 

Btu/ft3

in WC

Btu/hr

kW

DMS

mm

in WC

 

 

M31SL

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

 

M50SL

Natural

1,000

7.0-13.0

90,000

26.38

29

3.454

2

3.0

*Liquid Propane

2,500

11.0

90,000

26.38

47

2.994

2

10.0

 

M75SL

Natural

1,000

7.0-13.0

110,000

32.24

22

3.988

2

3.0

*Liquid Propane

2,500

11.0

110,000

32.24

44

2.184

2

10.0

 

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

Gas Specifications for CE Approved Dryers**

 

Gas

 

 

Nominal

Supply

Gross

Fuel

Orifice Size

Orifice

Burner

Model

 

 

Heating Value

Pressure

Heat Input

(Injector)

Pressure

Type

 

 

Consumption

 

 

 

 

 

 

 

 

 

 

 

Quantity

 

 

 

 

 

 

Btu/ft3

mb

Btu/hr

kW

 

DMS

mm

mb

 

Natural (I

/I

 

)

1,000

15-30

55,000

16.12

1.557 M3/H

22

3.988

1

6.9

 

 

2H

2E

 

 

 

 

 

 

 

 

 

 

Natural (I

)

 

 

830

20-35

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

 

2L

 

 

 

 

 

 

 

 

 

 

 

M31SL

Natural (I

2 E LL

)

830

15-30

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

*Natural (I2E+)

1,000

20

55,000

16.12

1.557 M3/H

31

3.048

1

 

 

830

25

55,000

16.12

1.876 M3/H

31

3.048

1

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

 

*Propane (I3+)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

 

Butane (I3B/P)

 

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

 

Propane (I3P)

 

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

 

Natural (I

/I

 

)

1,000

15-30

90,000

26.38

2.549 M3/H

29

3.454

2

7.2

 

 

2H

2E

 

 

 

 

 

 

 

 

 

 

Natural (I

)

 

 

830

20-35

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

 

 

2L

 

 

 

 

 

 

 

 

 

 

 

M50SL

Natural (I2 E LL )

830

15-30

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

*Natural (I2E+)

1,000

20

90,000

26.38

2.549 M3/H

35

2.794

2

 

 

830

25

90,000

26.38

3.071 M3/H

35

2.794

2

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

90,000

26.38

1.901 kg/H

50

1.778

2

 

*Propane (I3+)

2,500

37

90,000

26.38

1.901 kg/H

50

1.778

2

 

Butane (I3B/P)

 

3,175

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

18.1

 

Propane (I3P)

 

2,500

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

24.9

 

Natural (I2H/I2E)

1,000

15-30

110,000

32.24

3.115 M3/H

22

3.988

2

6.9

 

Natural (I

)

 

 

830

20-35

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

 

 

2L

 

 

 

 

 

 

 

 

 

 

 

M75SL

Natural (I2 E LL )

830

15-30

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

*Natural (I2E+)

1,000

20

110,000

32.24

3.115 M3/H

31

3.048

2

 

 

830

25

110,000

32.24

3.753 M3/H

31

3.048

2

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

110,000

32.24

2.324 kg/H

48

1.930

2

 

*Propane (I3+)

2,500

37

110,000

32.24

2.324 kg/H

48

1.930

2

 

Butane (I3B/P)

 

3,175

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

18.1

 

Propane (I3P)

 

2,500

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

24.9

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

113431 - 10

www.amdry.com

19

Image 19
Contents American Dryer Corporation M31SL / M50SL / M75SL Installation/Operator ManualRetain This Manual in a Safe Place for Future Reference Table of Contents What To Do If You Smell Gas Safety PrecautionsCE only 37.78 cm M31SL SpecificationsM31SL Specifications 40.64 cm M50SL SpecificationsM50SL Specifications M75SL Specifications M75SL Specifications Dryer Enclosure Requirements Installation ProceduresUnpacking/Setting Up Location RequirementsExhaust Requirements Fresh Air Supply RequirementsDomestic Type I M31SL, M50SL Only Vertical Venting Outside Ductwork ProtectionSingle Dryer Venting Horizontal VentingElectrical Requirements Electrical InformationElectric Models Only Electrical Service Specifications Gas and Steam Models OnlyFor CE Models Only Single-Phase 1ø Wiring Connections/HookupGrounding Electrical ConnectionsCE and Australian Dryers Gas InformationM31SL Piping/Connections Gas Specifications for AGA Approved Dryers AustraliaConverting from One Family Gas to Another Regulated Gas Valve Gas Pressure AdjustmentConversion from Propane or Butane Gas to Natural Gas Steam Coil pH Level Gas Pressure TestingGas Pressure Test Procedure Steam InformationWater Information Preoperational Test Preparation for Operation/Start-UpShutdown Instructions Preoperational InstructionsCoin Models Non-Coin ModelsWarranty Information Service/Parts InformationRoutine Maintenance Standard Label AGA Label CE Label Data Label InformationADC Part No 10 06/04/08