American Dryer Corp manual M31SL Specifications, 37.78 cm

Page 6

M31SL Specifications _______________________________________________________________

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

30 lb

 

13.61 kg

 

TUMBLER DIAMETER

 

30”

 

76.20 cm

 

TUMBLER DEPTH

 

 

 

27”

 

68.58 cm

 

TUMBLER VOLUME

 

 

 

11.04 cu ft

312.62 L

 

TUMBLER/DRIVE MOTOR

 

1/4 hp

 

0.19 kW

 

BLOWER/FAN MOTOR

 

1/2 hp

 

0.37 kW

 

DOOR OPENING (DIAMETER)

 

19-3/8”

 

49.21 cm

 

DOOR SILL HEIGHT

 

 

 

14-7/8”

 

37.78 cm

 

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

 

DRYERS PER 20’/40’ CONTAINER

 

 

12 / 28

 

 

DRYERS PER 48’/53’ TRUCK

 

 

34 / 38

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

285 lb

 

129.27 kg

 

 

APPROXIMATE SHIPPING WEIGHT

310 lb

 

140.61 kg

 

Gas

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

55,000 Btu/hr

13,860 kcal/hr

 

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

INLET PIPE CONNECTION

 

 

1/2” M.N.P.T.

 

 

 

 

 

 

 

 

3/8” M.B.S.P.T. (CE and Australia Only)

 

 

VOLTAGE AVAILABLE

 

200-416V

1,3ø

2,3,4w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

285 lb

 

129.27 kg

 

 

APPROXIMATE SHIPPING WEIGHT

310 lb

 

140.61 kg

 

 

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

Electric

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

 

 

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

7.9

 

26,962

 

6,794

 

 

 

 

 

 

8.3

 

28,327

 

7,138

 

 

 

 

 

 

9.0

 

30,716

 

7,740

 

 

 

 

 

 

11.3

 

38,566

 

9,719

 

 

 

 

 

 

12.4

 

42,320

 

10,665

 

 

 

 

 

 

12.5

 

42,661

 

10,751

 

 

 

 

 

 

13.5

 

46,074

 

11,611

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

305 lb

 

138.35 kg

 

Steam

APPROXIMATE SHIPPING WEIGHT

330 lb

 

149.69 kg

 

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

 

 

 

 

 

 

 

 

STEAM CONSUMPTION

 

63 lb/hr

 

28.58 kg/hr

 

 

OPERATING STEAM PRESSURE

150 psi max

10.34 bar

 

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

1.75 Bhp

 

 

 

SUPPLY CONNECTION

 

 

1/2” F.N.P.T.

 

 

 

RETURN CONNECTION

 

 

1/2” M.N.P.T.

 

 

Shaded areas are stated in metric equivalents

 

 

 

9/30/05

Note

!The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

6

American Dryer Corp.

113431 - 10

Image 6
Contents M31SL / M50SL / M75SL Installation/Operator Manual American Dryer CorporationRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only M31SL Specifications 37.78 cmM31SL Specifications M50SL Specifications 40.64 cmM50SL Specifications M75SL Specifications M75SL Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Dryer Enclosure RequirementsFresh Air Supply Requirements Exhaust RequirementsDomestic Type I M31SL, M50SL Only Horizontal Venting Outside Ductwork ProtectionSingle Dryer Venting Vertical VentingElectrical Information Electrical RequirementsElectrical Service Specifications Gas and Steam Models Only Electric Models OnlyElectrical Connections Single-Phase 1ø Wiring Connections/HookupGrounding For CE Models OnlyGas Information CE and Australian DryersM31SL Gas Specifications for AGA Approved Dryers Australia Piping/ConnectionsConverting from One Family Gas to Another Gas Pressure Adjustment Regulated Gas ValveConversion from Propane or Butane Gas to Natural Gas Steam Information Gas Pressure TestingGas Pressure Test Procedure Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestNon-Coin Models Preoperational InstructionsCoin Models Shutdown InstructionsService/Parts Information Warranty InformationRoutine Maintenance Data Label Information Standard Label AGA Label CE LabelADC Part No 10 06/04/08