American Dryer Corp D-40 installation manual Preoperational Instructions, Coin Models

Page 39

5. Make a complete operational check of ALL operating controls.

NOTE: If computer program changes are required, refer to the computer programming section of the manual supplied with the dryer.

6.The dryer should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functioning properly.

BASKET COATING

The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove this coating.

7.Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to see if the blower wheel (impellor/fan) is rotating in the proper direction. Looking from the front, the blower wheel (impellor/fan) should spin in the clockwise (CW) direction. If it is, the phasing is correct. If the phasing is incorrect, reverse two (2) of the three (3) leads at connections L1, L2, and L3 of the power supply to the dryer.

IMPORTANT: If the blower wheel (impellor/fan) is rotating in the wrong direction, this will not only drastically reduce drying efficiency, but it can also cause premature component failure.

K. PREOPERATIONAL INSTRUCTIONS

COIN MODELS

1.Automatic Mode (Microprocessor Controller [Computer] Models)

a.When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read “FILL” and/or “Amount To Start.”

b.Insert coins.

Once correct “Amount To Start” has been inserted, the L.E.D. display will read “PUSH.”

c.Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start, the L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. display will read “00” and count upward as time elapses.

IMPORTANT: If the door is opened during a cycle, both the heat and motor will stop. However, the microprocessor controller (computer) will continue to count downward in time. Continuation of the cycle will resume only after the door has been closed and any other of the three (3) temperature selection buttons is again depressed.

d.Once the preprogrammed dryness level and cool down period have been reached, or the maximum automatic time has expired, the tone (buzzer) will sound for 5-seconds, and the L.E.D. display will read “donE,” at which time the dryer will shut off.

35

Image 39
Contents Installation Manual Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Routine Maintenance Receiving and Handling Important InformationExplosion could Result Safety PrecautionsStandards Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Requirements Electrical InformationMust be Provided SINGLE-PHASE 1Ø Electrical Connection Leads Important a Circuit Servicing Each Dryer Must be Provided Important a Circuit Servicing Each Dryer Must be Provided 40 GAS Steam GAS Information Type of GAS Page Page Steam Information Operating Steam PressurePage Compressed AIR Pressure AIR Supply Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP GAS Models only Preoperational TestsCoin Models Preoperational InstructionsPage OPL Models Page SERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsLint Drawer Removal Data Label Data Label InformationSerial Number TIM ING Legend Reversing Timer SPIN/DWELL AdjustmentsProcedure for Functional Check Replacement Components Page F.E. Fire Suppression System F.S.S S. In ActionBefore YOU Start Check Local Codes and Permits InstallationWater Connections Optional Manual Bypass Electrical Requirements System ResetParts Break Down Comp x 3/8 M.P.T. Brass Connector 822752 ADC 113370 1 03/25/02-25

D-40 specifications

American Dryer Corp has long been recognized as a leader in the manufacturing of high-efficiency commercial dryers, and the D-40 model is a prime example of their commitment to delivering quality, performance, and technological advancements. The D-40 is designed to meet the rigorous demands of laundromats, hotels, and other commercial laundry facilities, offering a perfect balance of power and efficiency.

One of the main features of the D-40 is its robust construction. Built with high-quality materials, this dryer ensures durability and longevity even in high-volume operations. The D-40 is equipped with a large capacity tumbler that can accommodate significant loads, making it an ideal choice for businesses that require efficient drying solutions.

The dryer utilizes a state-of-the-art microprocessor control system, allowing users to program multiple drying cycles tailored to specific fabric types or customer preferences. This technology enables precise drying times and temperatures, which helps to prevent damage to garments while maximizing efficiency. The control panel is user-friendly, featuring clear displays and intuitive navigation, ensuring that operators can quickly set up and adjust cycles as needed.

In terms of energy efficiency, the D-40 is engineered with advanced drying technologies that reduce utility costs. Its high-performance gas burners and optimized airflow design allow for rapid heat distribution, which significantly shortens drying times. The dryer also features a reliable heat exchanger system that ensures consistent heat output while minimizing energy consumption.

Another noteworthy characteristic of the D-40 is its sound-dampening design. The dryer is equipped with noise-reduction technology, allowing it to operate quietly, which is particularly beneficial in environments where noise may disrupt customers or staff.

Safety features are also of paramount importance in the D-40’s design. It includes a protective door interlock system that ensures the dryer cannot operate when the door is open, reducing the risk of accidents. Moreover, the D-40 has been designed with easy access for maintenance, making it simpler for technicians to perform routine checks and repairs.

In conclusion, the American Dryer Corp D-40 stands out in the competitive landscape of commercial dryers by combining high-capacity performance with energy efficiency, advanced technology, and a commitment to safety and durability. Its innovative features make it an ideal choice for businesses looking to optimize their laundry operations.